  • Maximum Voltage Rating: 690V AC
  • Ambient Air Temperature For Operation: -20-55°C without derating IEC 60947 || -30-60°C with derating IEC 60947
  • Network Frequency: <= 400 Hz
  • Phase Failure Sensitivity: yes IEC 60947-4-1
  • Ambient Air Temperature For Storage: -40-70°C
  • Maximum Operating Temperature: 131 Degrees F

Specifications

Part Number LR2K0316
Brand Schneider Electric
Auxiliary Contact Form 1NC/1NO
Minimum Overload Relay Current Setting 8:00 AM
Maximum Overload Relay Current Setting 11.5 A
Trip Class 10A
Overload Protection Type Thermal
Depth 2.28
Body Height - Relay 2.28 in
Width 1.77
Height 2.56"
Overall Height - Relay 2.28 in
Body Height 2.28 in
Overall Height 2.28 in
Item Overload Relay
Maximum Voltage Rating 690V AC
Standards BS 4941, IEC 60947, NF C 63-650, REACH, RoHS, VDE 0660
Trip Class - Overload 10
For Use With TeSys K AC or DC IEC Contactor
Features Single Phase Sensitivity; Differential
Use With - Contactors and Starters LC7K, LP1K, LP4K Contactors, Mfr. Series LC1K
Sensing Method Bimetallic
Number of Poles 3
Starter Type IEC
Product Name TeSys LRK
Product Or Component Type differential thermal overload relay
Ambient Air Temperature For Operation -20-55°C without derating IEC 60947 || -30-60°C with derating IEC 60947
Thermal Protection Adjustment Range 8-11.5 A
Control Type Red push-button trip test function || Blue push-button stop and manual reset || selector switch manual or automatic reset
Mechanical Robustness shocks NO contact10 Gn for 11 ms IEC 60068-2-27 || shocks NC contact10 Gn for 11 ms IEC 60068-2-27 || vibrations NO contact2 Gn, 5 to 300 Hz IEC 60068-2-6 || vibrations NC contact2 Gn, 5 to 300 Hz IEC 60068-2-6
Protective Treatment TC IEC 60068 || TC DIN 50016
Flame Retardance V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Associated Fuse Rating 6 A gG signalling circuit VDE 0660 || 6 A gG signalling circuit IEC 60947
Connections - Terminals screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Network Type DC || AC
Power Dissipation Per Pole 2 W
Network Frequency <= 400 Hz
Device Short Name LR2K
Fire Resistance 850°C IEC 60695-2-1
Range TeSys
Phase Failure Sensitivity yes IEC 60947-4-1
Ambient Air Temperature For Storage -40-70°C
Product Compatibility LC7K || LP1K || LC1K || LP4K
Thermal Overload Class class 10A IEC 60947-4-1
Local Signalling trip indicator Yellow)
Product Certifications UL || CSA || UKCA
Operating Altitude 6561.68 ft (2000 m) without derating
Tightening Torque 1.3 N.m screw clamp terminals Philips No 2 || 1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
Relay Application motor protection
Maximum Operating Temperature 131 Degrees F
Minimum Operating Temperature -4 Degrees F
IP Rating IP22
Mounting Style Direct To Contactor
Compatible with Series TeSys Deca, TeSys K
Relay Style IEC
Reset Type Auto, Manual
Terminal Connection Type Screw Clamp Terminals
Rated Insulation Voltage power circuit 690 V BS 4941 || power circuit 690 V IEC 60947 || power circuit 750 V VDE 0110 group C || power circuit 600 V CSA C22.2 No 14
Conventional Free Air Thermal Current 6 A signalling circuit
Rated Operational Voltage <= 690 V power circuit || 690 V AC AC-15 signalling circuit || 250 V DC DC-13 signalling circuit
Trip Clss 10A

Description

The Schneider Electric LR2K0316 is a differential thermal overload relay for use with a TeSys K AC or DC IEC contactor. This overload relay protects motors from damage by monitoring current and tripping when an overload condition is detected, with a setting range of 8 to 11.5 A and a maximum voltage rating of 690V AC. It features single-phase sensitivity and complies with standards including BS 4941, IEC 60947, NF C 63-650, REACH, RoHS, and VDE 0660.

Shipping This item ships to USA

Processing Time:

All orders at Pro Replacement Parts are processed and shipped within 1-2 business days. For orders placed before 12 PM EST, we offer same-day shipping whenever possible. We aim to ensure that your order reaches you as quickly as possible.

Delivery Timeframe:

Most orders are delivered within 3–5 business days via UPS Ground. This is an estimated delivery timeframe, not a guarantee. Timing can vary by product availability, destination, holidays, weather, and carrier delays. Freight shipments may take longer.

Expedited Shipping:

UPS 2nd Day Air is available for eligible orders at checkout. Rates and estimated delivery dates are calculated at checkout. Two-business-day transit begins after shipment; processing time still applies.

Shipping Methods:

  • Items exceeding 50” in width or 70 lbs in weight are shipped via Freight Carrier. You will be contacted by the carrier to schedule a delivery time.
  • Items under 50” in width and 70 lbs in weight will be shipped via UPS or FedEx as a small package service.

Freight Shipments:

Freight shipments are delivered curbside in residential areas. You may need assistance to move the package indoors, or you can unbox the shipment and carry each piece inside individually. While some drivers may help move a shipment into a garage or carport, this is not guaranteed. For Inside Delivery requests, please contact us at the time of your order (additional fees apply). Email: support@proreplacementparts.com

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Wide Selection of Brands: At our store, you'll find an extensive range of electric motors from top brands in the industry. We carefully select our inventory to ensure that you have access to the best and most reliable products on the market. Whether you need a motor for an industrial machine, a household appliance, or a specialized project, we have something for everyone.

Customer-Centric Service: We believe in putting our customers first. Our team is committed to providing you with personalized service and support throughout your buying journey. From helping you choose the right motor for your needs to answering any queries you have after purchase, we're here to assist you every step of the way.

Competitive Pricing: We strive to offer our high-quality electric motors at competitive prices. Our goal is to provide you with the best value, ensuring that you get a top-performing motor without breaking the bank. Plus, our regular deals and promotions mean that you can save even more when you shop with us.

Reliable Shipping and Handling: While we don't offer same-day shipping, we understand the importance of timely delivery. That's why we work with reliable shipping partners to ensure that your order is processed, shipped, and delivered efficiently. You can trust us to get your electric motor to you in excellent condition and within a reasonable timeframe.

Knowledgeable Support: Our team is knowledgeable about the wide range of electric motors we offer. We can provide you with detailed information and specifications for each product, helping you make an informed decision. If you have any questions or need advice, our experts are just a call or email away.

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

Description

  • Maximum Voltage Rating: 690V AC
  • Ambient Air Temperature For Operation: -20-55°C without derating IEC 60947 || -30-60°C with derating IEC 60947
  • Network Frequency: <= 400 Hz
  • Phase Failure Sensitivity: yes IEC 60947-4-1
  • Ambient Air Temperature For Storage: -40-70°C
  • Maximum Operating Temperature: 131 Degrees F

Specifications

Part Number LR2K0316
Brand Schneider Electric
Auxiliary Contact Form 1NC/1NO
Minimum Overload Relay Current Setting 8:00 AM
Maximum Overload Relay Current Setting 11.5 A
Trip Class 10A
Overload Protection Type Thermal
Depth 2.28
Body Height - Relay 2.28 in
Width 1.77
Height 2.56"
Overall Height - Relay 2.28 in
Body Height 2.28 in
Overall Height 2.28 in
Item Overload Relay
Maximum Voltage Rating 690V AC
Standards BS 4941, IEC 60947, NF C 63-650, REACH, RoHS, VDE 0660
Trip Class - Overload 10
For Use With TeSys K AC or DC IEC Contactor
Features Single Phase Sensitivity; Differential
Use With - Contactors and Starters LC7K, LP1K, LP4K Contactors, Mfr. Series LC1K
Sensing Method Bimetallic
Number of Poles 3
Starter Type IEC
Product Name TeSys LRK
Product Or Component Type differential thermal overload relay
Ambient Air Temperature For Operation -20-55°C without derating IEC 60947 || -30-60°C with derating IEC 60947
Thermal Protection Adjustment Range 8-11.5 A
Control Type Red push-button trip test function || Blue push-button stop and manual reset || selector switch manual or automatic reset
Mechanical Robustness shocks NO contact10 Gn for 11 ms IEC 60068-2-27 || shocks NC contact10 Gn for 11 ms IEC 60068-2-27 || vibrations NO contact2 Gn, 5 to 300 Hz IEC 60068-2-6 || vibrations NC contact2 Gn, 5 to 300 Hz IEC 60068-2-6
Protective Treatment TC IEC 60068 || TC DIN 50016
Flame Retardance V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Associated Fuse Rating 6 A gG signalling circuit VDE 0660 || 6 A gG signalling circuit IEC 60947
Connections - Terminals screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Network Type DC || AC
Power Dissipation Per Pole 2 W
Network Frequency <= 400 Hz
Device Short Name LR2K
Fire Resistance 850°C IEC 60695-2-1
Range TeSys
Phase Failure Sensitivity yes IEC 60947-4-1
Ambient Air Temperature For Storage -40-70°C
Product Compatibility LC7K || LP1K || LC1K || LP4K
Thermal Overload Class class 10A IEC 60947-4-1
Local Signalling trip indicator Yellow)
Product Certifications UL || CSA || UKCA
Operating Altitude 6561.68 ft (2000 m) without derating
Tightening Torque 1.3 N.m screw clamp terminals Philips No 2 || 1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
Relay Application motor protection
Maximum Operating Temperature 131 Degrees F
Minimum Operating Temperature -4 Degrees F
IP Rating IP22
Mounting Style Direct To Contactor
Compatible with Series TeSys Deca, TeSys K
Relay Style IEC
Reset Type Auto, Manual
Terminal Connection Type Screw Clamp Terminals
Rated Insulation Voltage power circuit 690 V BS 4941 || power circuit 690 V IEC 60947 || power circuit 750 V VDE 0110 group C || power circuit 600 V CSA C22.2 No 14
Conventional Free Air Thermal Current 6 A signalling circuit
Rated Operational Voltage <= 690 V power circuit || 690 V AC AC-15 signalling circuit || 250 V DC DC-13 signalling circuit
Trip Clss 10A

Description

The Schneider Electric LR2K0316 is a differential thermal overload relay for use with a TeSys K AC or DC IEC contactor. This overload relay protects motors from damage by monitoring current and tripping when an overload condition is detected, with a setting range of 8 to 11.5 A and a maximum voltage rating of 690V AC. It features single-phase sensitivity and complies with standards including BS 4941, IEC 60947, NF C 63-650, REACH, RoHS, and VDE 0660.

Shipping

Shipping This item ships to USA

Processing Time:

All orders at Pro Replacement Parts are processed and shipped within 1-2 business days. For orders placed before 12 PM EST, we offer same-day shipping whenever possible. We aim to ensure that your order reaches you as quickly as possible.

Delivery Timeframe:

Most orders are delivered within 3–5 business days via UPS Ground. This is an estimated delivery timeframe, not a guarantee. Timing can vary by product availability, destination, holidays, weather, and carrier delays. Freight shipments may take longer.

Expedited Shipping:

UPS 2nd Day Air is available for eligible orders at checkout. Rates and estimated delivery dates are calculated at checkout. Two-business-day transit begins after shipment; processing time still applies.

Shipping Methods:

  • Items exceeding 50” in width or 70 lbs in weight are shipped via Freight Carrier. You will be contacted by the carrier to schedule a delivery time.
  • Items under 50” in width and 70 lbs in weight will be shipped via UPS or FedEx as a small package service.

Freight Shipments:

Freight shipments are delivered curbside in residential areas. You may need assistance to move the package indoors, or you can unbox the shipment and carry each piece inside individually. While some drivers may help move a shipment into a garage or carport, this is not guaranteed. For Inside Delivery requests, please contact us at the time of your order (additional fees apply). Email: support@proreplacementparts.com

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Why Buy From Us?

Wide Selection of Brands: At our store, you'll find an extensive range of electric motors from top brands in the industry. We carefully select our inventory to ensure that you have access to the best and most reliable products on the market. Whether you need a motor for an industrial machine, a household appliance, or a specialized project, we have something for everyone.

Customer-Centric Service: We believe in putting our customers first. Our team is committed to providing you with personalized service and support throughout your buying journey. From helping you choose the right motor for your needs to answering any queries you have after purchase, we're here to assist you every step of the way.

Competitive Pricing: We strive to offer our high-quality electric motors at competitive prices. Our goal is to provide you with the best value, ensuring that you get a top-performing motor without breaking the bank. Plus, our regular deals and promotions mean that you can save even more when you shop with us.

Reliable Shipping and Handling: While we don't offer same-day shipping, we understand the importance of timely delivery. That's why we work with reliable shipping partners to ensure that your order is processed, shipped, and delivered efficiently. You can trust us to get your electric motor to you in excellent condition and within a reasonable timeframe.

Knowledgeable Support: Our team is knowledgeable about the wide range of electric motors we offer. We can provide you with detailed information and specifications for each product, helping you make an informed decision. If you have any questions or need advice, our experts are just a call or email away.

Warranty/Returns

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

LR2K0316 Schneider Electric Overload Relay, 1NO/1NC, up to 690V AC

LR2K0316 Schneider Electric Overload Relay, 1NO/1NC, up to 690V AC

$143.27
Add to wishlist
LR2K0316 Schneider Electric Overload Relay, 1NO/1NC, up to 690V AC

LR2K0316 Schneider Electric Overload Relay, 1NO/1NC, up to 690V AC

Your Price:
$143.27

No reviews yet. Be the first to review this product!

3 visitors right now
3 visitors have this item in their cart right now
3 people have bought this item
3 % of people buy 2 or more

Recently viewed products

3 Visitor Right Now
3 visitors have this item in their cart right now
Only 3 left! .. people are viewing this, and 3 recently purchased it
3 People have recently bought this