- Coil Voltage: 24V-60V AC/DC
- HP @ 3 Phase - 575V: 20 hp
- Enclosure NEMA Rating: No Enclosure
- Signalling Circuit Frequency: 25 to 400 Hz
- Rated Breaking Capacity: 450 A @ 440V
- Rated Making Capacity: 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Specifications
| Part Number | LC1D25BNE |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 24V-60V AC/DC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Height | 3.35 in |
| Overall Depth | 3.62 in |
| Overall Width | 1.77 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| HP @ 3 Phase - 575V | 20 hp |
| Enclosure NEMA Rating | No Enclosure |
| Series | TeSys Deca |
| Net Weight | 0.433 kg |
| Operating Time | 45 to 55 ms (Closing), 20 to 90 ms (Opening) |
| Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50 Hz AC-3), 11 kW (at 380 to 400V AC 50 Hz AC-3), 11 kW (at 415V AC 50 Hz AC-3), 11 kW (at 440V AC 50 Hz AC-3), 15 kW (at 500V AC 50 Hz AC-3), 15 kW (at 660 to 690V AC 50 Hz AC-3), 5.5 kW (at 220 to 230V AC 50 Hz AC-3e), 11 kW (at 380 to 400V AC 50 Hz AC-3e), 11 kW (at 415V AC 50 Hz AC-3e), 11 kW (at 440V AC 50 Hz AC-3e), 15 kW (at 500V AC 50 Hz AC-3e), 15 kW (at 660 to 690V AC 50 Hz AC-3e) |
| Mechanical Durability | 15 Mcycles |
| Non-Overlap Time | 1.5 ms |
| Hold VA | 0.9 VA |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Application | Motor Control, Resistive Load |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Electrical Durability | 2 Mcycles (21 A, AC-3, Less than 440 V); 0.9 Mcycles (40 A, AC-1, Less than 440 V); 2 Mcycles (21 A, AC-3e, Less than 440 V) |
| Fire Rating | UL 94 V1 |
| Rated Insulation Volts | 690V |
| Rated Breaking Capacity | 450 A @ 440V |
| IP Rating | IP20 |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
| Inrush VA | 15 VA |
| Environmental Attributes | Mercury Free, Pollution Degree 3 |
| Rated Short-Time Withstand Current | 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit) |
| Impulse Withstand Voltage | 6 kV |
| Impedance | 2 mOhm |
| Watts Loss | 0.6W |
| Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
| Operating Speed | 3600 cycles per hr |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
| Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
| Overvoltage Category | CAT III |
| Switching Voltage | 17 V (Signalling Circuit) |
| Switching Current | 5 mA (Signalling Circuit) |
| Features | Built-In Bi-Directional Peak Limiting |
| Includes Protective Cover | Yes |
| Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Horsepower @ Three Phase - 600V AC | 20 hp |
| Mounting Style | DIN Rail, Plate |
| Horsepower @ Three Phase - 480V AC | 15 hp |
| Minimum Operating Temperature | -40 Degrees F |
| Electrical Operating Durability | 2,000,000, 900,000 |
| Number of Normally Open Main Contacts | 3 |
| Maximum Operating Temperature | 140 Degrees F |
| Embedded Surge Suppressor | No |
| Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
| Maximum Voltage Rating | 690V AC |
| Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Contactor Style | IEC |
| Includes Auxiliary Contacts | Yes |
| Mechanical Operating Durability | 15,000,000 |
| Horsepower @ Single Phase - 120V AC | 2 hp |
| Horsepower @ Single Phase - 240V AC | 3 hp |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Inductive | 25 A |
| Frequency | 50/60 Hz |
| Phase | Three |
| Full Load Current - Resistive | 40 A |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D25BNE is a TeSys IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It features a 24V-60V AC/DC coil, three poles rated for 25A, and screw clamp terminals, with 1NC/1NO auxiliary contacts. It is listed to UL 60947-4-1 and certified to multiple standards including CCC, CSA, and EN/IEC 60947-4-1.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 24V-60V AC/DC
- HP @ 3 Phase - 575V: 20 hp
- Enclosure NEMA Rating: No Enclosure
- Signalling Circuit Frequency: 25 to 400 Hz
- Rated Breaking Capacity: 450 A @ 440V
- Rated Making Capacity: 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Specifications
| Part Number | LC1D25BNE |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 24V-60V AC/DC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Height | 3.35 in |
| Overall Depth | 3.62 in |
| Overall Width | 1.77 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| HP @ 3 Phase - 575V | 20 hp |
| Enclosure NEMA Rating | No Enclosure |
| Series | TeSys Deca |
| Net Weight | 0.433 kg |
| Operating Time | 45 to 55 ms (Closing), 20 to 90 ms (Opening) |
| Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50 Hz AC-3), 11 kW (at 380 to 400V AC 50 Hz AC-3), 11 kW (at 415V AC 50 Hz AC-3), 11 kW (at 440V AC 50 Hz AC-3), 15 kW (at 500V AC 50 Hz AC-3), 15 kW (at 660 to 690V AC 50 Hz AC-3), 5.5 kW (at 220 to 230V AC 50 Hz AC-3e), 11 kW (at 380 to 400V AC 50 Hz AC-3e), 11 kW (at 415V AC 50 Hz AC-3e), 11 kW (at 440V AC 50 Hz AC-3e), 15 kW (at 500V AC 50 Hz AC-3e), 15 kW (at 660 to 690V AC 50 Hz AC-3e) |
| Mechanical Durability | 15 Mcycles |
| Non-Overlap Time | 1.5 ms |
| Hold VA | 0.9 VA |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Application | Motor Control, Resistive Load |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Electrical Durability | 2 Mcycles (21 A, AC-3, Less than 440 V); 0.9 Mcycles (40 A, AC-1, Less than 440 V); 2 Mcycles (21 A, AC-3e, Less than 440 V) |
| Fire Rating | UL 94 V1 |
| Rated Insulation Volts | 690V |
| Rated Breaking Capacity | 450 A @ 440V |
| IP Rating | IP20 |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
| Inrush VA | 15 VA |
| Environmental Attributes | Mercury Free, Pollution Degree 3 |
| Rated Short-Time Withstand Current | 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit) |
| Impulse Withstand Voltage | 6 kV |
| Impedance | 2 mOhm |
| Watts Loss | 0.6W |
| Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
| Operating Speed | 3600 cycles per hr |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
| Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
| Overvoltage Category | CAT III |
| Switching Voltage | 17 V (Signalling Circuit) |
| Switching Current | 5 mA (Signalling Circuit) |
| Features | Built-In Bi-Directional Peak Limiting |
| Includes Protective Cover | Yes |
| Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Horsepower @ Three Phase - 600V AC | 20 hp |
| Mounting Style | DIN Rail, Plate |
| Horsepower @ Three Phase - 480V AC | 15 hp |
| Minimum Operating Temperature | -40 Degrees F |
| Electrical Operating Durability | 2,000,000, 900,000 |
| Number of Normally Open Main Contacts | 3 |
| Maximum Operating Temperature | 140 Degrees F |
| Embedded Surge Suppressor | No |
| Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
| Maximum Voltage Rating | 690V AC |
| Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Contactor Style | IEC |
| Includes Auxiliary Contacts | Yes |
| Mechanical Operating Durability | 15,000,000 |
| Horsepower @ Single Phase - 120V AC | 2 hp |
| Horsepower @ Single Phase - 240V AC | 3 hp |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Inductive | 25 A |
| Frequency | 50/60 Hz |
| Phase | Three |
| Full Load Current - Resistive | 40 A |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D25BNE is a TeSys IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It features a 24V-60V AC/DC coil, three poles rated for 25A, and screw clamp terminals, with 1NC/1NO auxiliary contacts. It is listed to UL 60947-4-1 and certified to multiple standards including CCC, CSA, and EN/IEC 60947-4-1.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!