  • Coil Voltage: 110V AC
  • HP @ 3 Phase - 575V: 15 hp
  • Enclosure NEMA Rating: No Enclosure
  • Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
  • Overvoltage Category: CAT III
  • Rated Making Capacity: 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)

Specifications

Part Number LC1D18F7
Brand Schneider Electric
Auxiliary Contact Form 1NC/1NO
Coil Voltage 110V AC
Number of Poles 3
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Working Height Up to 9842.52 ft
Overall Height 3.03 in
Overall Depth 3.39 in
Overall Width 1.77 in
Item IEC Magnetic Contactor
Number of Auxillary Contacts 2
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
HP @ 3 Phase - 575V 15 hp
Series TeSys Deca
Reversing No
Enclosure NEMA Rating No Enclosure
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Application Motor Control, Resistive Load
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Features Without Built-In Suppressor Module
Overvoltage Category CAT III
Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Signalling Circuit Frequency 25 to 400 Hz
Tightening Torque 1.7 Nm
Switching Current 5 mA (Signalling Circuit)
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
IP Rating IP20
Inrush VA 70 VA
Operating Speed 3600 cycles per hr
Net Weight 0.33 kg
Fuse Amps 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Electrical Durability 1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V); 1.65 Mcycles (18 A, AC-3e, Less than 440 V)
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Switching Voltage 17 V (Signalling Circuit)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Impulse Withstand Voltage 6 kV
Watts Loss 2 to 3W
Rated Breaking Capacity 300 A @ 440V
Rated Insulation Volts 600/690V
Rated Short-Time Withstand Current 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impedance 2.5 mOhm
Includes Protective Cover Yes
Mechanical Durability 15 Mcycles
Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Max. Operating Watts 4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Fire Rating UL 94 V1
Non-Overlap Time 1.5 ms
Includes Auxiliary Contacts Yes
Horsepower @ Three Phase - 600V AC 15 hp
Contactor Style IEC
Minimum Operating Temperature -40 Degrees F
Number of Normally Open Main Contacts 3
Mounting Style DIN Rail, Plate
Maximum Voltage Rating 690V AC
Frequency 50/60 Hz
Resistance Properties Fire Resistant, Insulation Resistant
Embedded Surge Suppressor No
Horsepower @ Single Phase - 240V AC 3 hp
Full Load Current - Inductive 18 A
Phase Three
Mechanical Operating Durability 15,000,000
NEMA Enclosure Rating No Enclosure
Horsepower @ Single Phase - 120V AC 1 hp
Maximum Operating Temperature 140 Degrees F
Horsepower @ Three Phase - 240V AC 5 hp
Electrical Operating Durability 1,000,000, 1,650,000
Horsepower @ Three Phase - 208V AC 5 hp
Horsepower @ Three Phase - 480V AC 10 hp
Pole Contact Composition 3 NO
Rated Operational Current 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Compatibility Code LC1D
Utilisation Category AC-1; AC-4; AC-3; AC-3e
Contact Compatibility M2
Protective Cover With
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Inrush Power in VA 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Conventional Free Air Thermal Current 10 A (at 140°F (60°C)) for signalling circuit; 32 A (at 140°F (60°C)) for power circuit
Control Circuit Type AC 50/60 Hz standard
Maximum Operating Rate 3600 cyc/h 140°F (60°C)
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Pollution Degree 3
Heat Dissipation 2 to 3 W at 50/60 Hz
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application Motor control; Resistive load
Power Dissipation Per Pole 2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e
Protective Treatment THIEC 60068-2-30
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Control Circuit Voltage 110 V AC 50/60 Hz
Full Load Current - Resistive 32 A
Ambient Air Temperature For Operation -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The Schneider Electric LC1D18F7 is a TeSys Deca IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It operates with a 110V AC coil voltage, is rated for 18 amps and 15 hp at 575V three-phase, and features screw clamp terminals with one normally-open and one normally-closed auxiliary contact. It complies with standards including UL 508, CSA, IEC 60947-4-1, and CCC.

Shipping and dispatch

Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.

Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.

Freight shipments

Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.

Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.

Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.

Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

Description

  • Coil Voltage: 110V AC
  • HP @ 3 Phase - 575V: 15 hp
  • Enclosure NEMA Rating: No Enclosure
  • Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
  • Overvoltage Category: CAT III
  • Rated Making Capacity: 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)

Specifications

Part Number LC1D18F7
Brand Schneider Electric
Auxiliary Contact Form 1NC/1NO
Coil Voltage 110V AC
Number of Poles 3
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Working Height Up to 9842.52 ft
Overall Height 3.03 in
Overall Depth 3.39 in
Overall Width 1.77 in
Item IEC Magnetic Contactor
Number of Auxillary Contacts 2
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
HP @ 3 Phase - 575V 15 hp
Series TeSys Deca
Reversing No
Enclosure NEMA Rating No Enclosure
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Application Motor Control, Resistive Load
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Features Without Built-In Suppressor Module
Overvoltage Category CAT III
Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Signalling Circuit Frequency 25 to 400 Hz
Tightening Torque 1.7 Nm
Switching Current 5 mA (Signalling Circuit)
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
IP Rating IP20
Inrush VA 70 VA
Operating Speed 3600 cycles per hr
Net Weight 0.33 kg
Fuse Amps 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Electrical Durability 1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V); 1.65 Mcycles (18 A, AC-3e, Less than 440 V)
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Switching Voltage 17 V (Signalling Circuit)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Impulse Withstand Voltage 6 kV
Watts Loss 2 to 3W
Rated Breaking Capacity 300 A @ 440V
Rated Insulation Volts 600/690V
Rated Short-Time Withstand Current 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impedance 2.5 mOhm
Includes Protective Cover Yes
Mechanical Durability 15 Mcycles
Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Max. Operating Watts 4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Fire Rating UL 94 V1
Non-Overlap Time 1.5 ms
Includes Auxiliary Contacts Yes
Horsepower @ Three Phase - 600V AC 15 hp
Contactor Style IEC
Minimum Operating Temperature -40 Degrees F
Number of Normally Open Main Contacts 3
Mounting Style DIN Rail, Plate
Maximum Voltage Rating 690V AC
Frequency 50/60 Hz
Resistance Properties Fire Resistant, Insulation Resistant
Embedded Surge Suppressor No
Horsepower @ Single Phase - 240V AC 3 hp
Full Load Current - Inductive 18 A
Phase Three
Mechanical Operating Durability 15,000,000
NEMA Enclosure Rating No Enclosure
Horsepower @ Single Phase - 120V AC 1 hp
Maximum Operating Temperature 140 Degrees F
Horsepower @ Three Phase - 240V AC 5 hp
Electrical Operating Durability 1,000,000, 1,650,000
Horsepower @ Three Phase - 208V AC 5 hp
Horsepower @ Three Phase - 480V AC 10 hp
Pole Contact Composition 3 NO
Rated Operational Current 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Compatibility Code LC1D
Utilisation Category AC-1; AC-4; AC-3; AC-3e
Contact Compatibility M2
Protective Cover With
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Inrush Power in VA 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Conventional Free Air Thermal Current 10 A (at 140°F (60°C)) for signalling circuit; 32 A (at 140°F (60°C)) for power circuit
Control Circuit Type AC 50/60 Hz standard
Maximum Operating Rate 3600 cyc/h 140°F (60°C)
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Pollution Degree 3
Heat Dissipation 2 to 3 W at 50/60 Hz
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application Motor control; Resistive load
Power Dissipation Per Pole 2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e
Protective Treatment THIEC 60068-2-30
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Control Circuit Voltage 110 V AC 50/60 Hz
Full Load Current - Resistive 32 A
Ambient Air Temperature For Operation -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The Schneider Electric LC1D18F7 is a TeSys Deca IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It operates with a 110V AC coil voltage, is rated for 18 amps and 15 hp at 575V three-phase, and features screw clamp terminals with one normally-open and one normally-closed auxiliary contact. It complies with standards including UL 508, CSA, IEC 60947-4-1, and CCC.

Shipping

Shipping and dispatch

Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.

Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.

Freight shipments

Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Why Buy From Us?

Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.

Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.

Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.

Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.

Warranty/Returns

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

LC1D18F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC, Screw Clamp

LC1D18F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC, Screw Clamp

$133.95
Add to wishlist
LC1D18F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC, Screw Clamp

LC1D18F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC, Screw Clamp

Your Price:
$133.95
★

No reviews yet. Be the first to review this product!

Recently viewed products