Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

LC1D09B7 Schneider Electric 3-Pole 1NO/1NC Magnetic Contactor, 24V AC Coil

SKU: LC1D09B7
Your Price:
$114.40
Shipping: $29.95 UPS Ground. Dispatch timing varies by product and supplier.US only. The exact cost is confirmed at checkout.
Add to wishlist
Checkout Secure

Great reasons to buy from us:

  • Image of Quality Guaranteed

    Quality

    Quality Guaranteed
  • Image of Fast Shipping

    Free shipping

    Fast Shipping
  • Image of Great Value

    Fast Shipping

    Great Value
  • Image of Secure Online Ordering

    Free shipping

    Secure Online Ordering
  • Coil Voltage: 24V AC
  • HP @ 3 Phase - 575V: 7 1/2 hp
  • Enclosure NEMA Rating: No Enclosure
  • HP @ 1 Phase - 230V: 1
  • Rated Breaking Capacity: 250 A @ 440V
  • Impulse Withstand Voltage: 6 kV

Specifications

Part Number LC1D09B7
Brand Schneider Electric
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24V AC
Number of Poles 3
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Working Height Up to 9842.52 ft
Overall Depth 3.39 in
Overall Height 3.03 in
Overall Width 1.77 in
Item IEC Magnetic Contactor
Number of Auxillary Contacts 2
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
HP @ 3 Phase - 575V 7 1/2 hp
Reversing No
Enclosure NEMA Rating No Enclosure
HP @ 1 Phase - 230V 1
Series TeSys Deca
Includes Protective Cover Yes
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Max. Operating Watts 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Tightening Torque 1.7 Nm
Fire Rating UL 94 V1
Rated Breaking Capacity 250 A @ 440V
Impulse Withstand Voltage 6 kV
Rated Short-Time Withstand Current 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability 0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V); 2 Mcycles (9 A, AC-3e, Less than 440 V)
Overvoltage Category CAT III
Non-Overlap Time 1.5 ms
Application Motor Control, Resistive Load
Impedance 2.5 mOhm
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts 600/690V
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Mechanical Durability 15 Mcycles
Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Signalling Circuit Frequency 25 to 400 Hz
Operating Speed 3600 cycles per hr
Fuse Amps 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
IP Rating IP20
Inrush VA 70 VA
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Current 5 mA (Signalling Circuit)
Switching Voltage 17 V (Signalling Circuit)
Features Without Built-In Suppressor Module
Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Net Weight 0.32 kg
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Watts Loss 2 to 3W
Horsepower @ Three Phase - 600V AC 7 1/2 hp
Horsepower @ Three Phase - 240V AC 2 hp
Mounting Style DIN Rail, Plate
Includes Auxiliary Contacts Yes
Horsepower @ Three Phase - 480V AC 5 hp
Horsepower @ Three Phase - 208V AC 2 hp
NEMA Enclosure Rating No Enclosure
Maximum Operating Temperature 140 Degrees F
Resistance Properties Fire Resistant, Insulation Resistant
Embedded Surge Suppressor No
Horsepower @ Single Phase - 120V AC 1/3 hp
Minimum Operating Temperature -40 Degrees F
Phase Three
Horsepower @ Single Phase - 240V AC 1 hp
Electrical Operating Durability 2,000,000, 600,000
Maximum Voltage Rating 690V AC
Contactor Style IEC
Full Load Current - Resistive 20 A
Mechanical Operating Durability 15,000,000
Frequency 50/60 Hz
Full Load Current - Inductive 9:00 AM
Number of Normally Open Main Contacts 3
Utilisation Category AC-4; AC-1; AC-3; AC-3e
Protective Cover With
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Inrush Power in VA 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Pole Contact Composition 3 NO
Compatibility Code LC1D
Pollution Degree 3
Conventional Free Air Thermal Current 25 A (at 140°F (60°C)) for power circuit; 10 A (at 140°F (60°C)) for signalling circuit
Rated Operational Current 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Contact Compatibility M2
Heat Dissipation 2 to 3 W at 50/60 Hz
Maximum Operating Rate 3600 cyc/h 140°F (60°C)
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Control Circuit Type AC 50/60 Hz standard
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Control Circuit Voltage 24 V AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protective Treatment THIEC 60068-2-30
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Contactor Application Resistive load; Motor control
Power Dissipation Per Pole 1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e
Ambient Air Temperature For Operation -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The Schneider Electric LC1D09B7 is a TeSys IEC magnetic contactor with a 24V AC coil and screw clamp terminals. This non-reversing, three-pole contactor switches power to a three-phase load, with one normally open and one normally closed auxiliary contact. It is rated for 7 1/2 hp at 575V three-phase and complies with standards including UL 508, CSA, IEC 60947-4-1, and CCC.

Shipping and dispatch

Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.

Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.

Freight shipments

Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.

Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.

Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.

Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

Description

  • Coil Voltage: 24V AC
  • HP @ 3 Phase - 575V: 7 1/2 hp
  • Enclosure NEMA Rating: No Enclosure
  • HP @ 1 Phase - 230V: 1
  • Rated Breaking Capacity: 250 A @ 440V
  • Impulse Withstand Voltage: 6 kV

Specifications

Part Number LC1D09B7
Brand Schneider Electric
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24V AC
Number of Poles 3
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Working Height Up to 9842.52 ft
Overall Depth 3.39 in
Overall Height 3.03 in
Overall Width 1.77 in
Item IEC Magnetic Contactor
Number of Auxillary Contacts 2
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
HP @ 3 Phase - 575V 7 1/2 hp
Reversing No
Enclosure NEMA Rating No Enclosure
HP @ 1 Phase - 230V 1
Series TeSys Deca
Includes Protective Cover Yes
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Max. Operating Watts 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Tightening Torque 1.7 Nm
Fire Rating UL 94 V1
Rated Breaking Capacity 250 A @ 440V
Impulse Withstand Voltage 6 kV
Rated Short-Time Withstand Current 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability 0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V); 2 Mcycles (9 A, AC-3e, Less than 440 V)
Overvoltage Category CAT III
Non-Overlap Time 1.5 ms
Application Motor Control, Resistive Load
Impedance 2.5 mOhm
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts 600/690V
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Mechanical Durability 15 Mcycles
Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Signalling Circuit Frequency 25 to 400 Hz
Operating Speed 3600 cycles per hr
Fuse Amps 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
IP Rating IP20
Inrush VA 70 VA
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Current 5 mA (Signalling Circuit)
Switching Voltage 17 V (Signalling Circuit)
Features Without Built-In Suppressor Module
Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Net Weight 0.32 kg
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Watts Loss 2 to 3W
Horsepower @ Three Phase - 600V AC 7 1/2 hp
Horsepower @ Three Phase - 240V AC 2 hp
Mounting Style DIN Rail, Plate
Includes Auxiliary Contacts Yes
Horsepower @ Three Phase - 480V AC 5 hp
Horsepower @ Three Phase - 208V AC 2 hp
NEMA Enclosure Rating No Enclosure
Maximum Operating Temperature 140 Degrees F
Resistance Properties Fire Resistant, Insulation Resistant
Embedded Surge Suppressor No
Horsepower @ Single Phase - 120V AC 1/3 hp
Minimum Operating Temperature -40 Degrees F
Phase Three
Horsepower @ Single Phase - 240V AC 1 hp
Electrical Operating Durability 2,000,000, 600,000
Maximum Voltage Rating 690V AC
Contactor Style IEC
Full Load Current - Resistive 20 A
Mechanical Operating Durability 15,000,000
Frequency 50/60 Hz
Full Load Current - Inductive 9:00 AM
Number of Normally Open Main Contacts 3
Utilisation Category AC-4; AC-1; AC-3; AC-3e
Protective Cover With
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Inrush Power in VA 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Pole Contact Composition 3 NO
Compatibility Code LC1D
Pollution Degree 3
Conventional Free Air Thermal Current 25 A (at 140°F (60°C)) for power circuit; 10 A (at 140°F (60°C)) for signalling circuit
Rated Operational Current 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Contact Compatibility M2
Heat Dissipation 2 to 3 W at 50/60 Hz
Maximum Operating Rate 3600 cyc/h 140°F (60°C)
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Control Circuit Type AC 50/60 Hz standard
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Control Circuit Voltage 24 V AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protective Treatment THIEC 60068-2-30
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Contactor Application Resistive load; Motor control
Power Dissipation Per Pole 1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e
Ambient Air Temperature For Operation -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The Schneider Electric LC1D09B7 is a TeSys IEC magnetic contactor with a 24V AC coil and screw clamp terminals. This non-reversing, three-pole contactor switches power to a three-phase load, with one normally open and one normally closed auxiliary contact. It is rated for 7 1/2 hp at 575V three-phase and complies with standards including UL 508, CSA, IEC 60947-4-1, and CCC.

Shipping

Shipping and dispatch

Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.

Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.

Freight shipments

Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Why Buy From Us?

Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.

Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.

Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.

Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.

Warranty/Returns

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

LC1D09B7 Schneider Electric 3-Pole 1NO/1NC Magnetic Contactor, 24V AC Coil

LC1D09B7 Schneider Electric 3-Pole 1NO/1NC Magnetic Contactor, 24V AC Coil

$114.40
Add to wishlist
LC1D09B7 Schneider Electric 3-Pole 1NO/1NC Magnetic Contactor, 24V AC Coil

LC1D09B7 Schneider Electric 3-Pole 1NO/1NC Magnetic Contactor, 24V AC Coil

Your Price:
$114.40
★

No reviews yet. Be the first to review this product!

Recently viewed products