Great reasons to buy from us:
-
Quality
Quality Guaranteed -
Free shipping
Fast Shipping -
Fast Shipping
Great Value -
Free shipping
Secure Online Ordering
- Coil Voltage: 110V AC
- Enclosure NEMA Rating: No Enclosure
- Rated Making Capacity: 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
- Impulse Withstand Voltage: 8 kV
- Control Circuit Voltage Limits: Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
- Signalling Circuit Frequency: Less Than 400 Hz
Specifications
| Part Number | LC1K1210F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | No Auxiliary Contacts |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | 6561.68 ft |
| Overall Depth | 2.24 in |
| Overall Width | 1.77 in |
| Overall Height | 2.28 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 1 |
| Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
| Enclosure NEMA Rating | No Enclosure |
| Frame / Series / Class / Code | TeSys |
| Series | TeSys K |
| Reversing | No |
| Rated Making Capacity | 110 A (AC Signalling Circuit), 144 A (AC Power Circuit) |
| Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
| Electrical Durability | 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V) |
| Impulse Withstand Voltage | 8 kV |
| Switching Current | 5 mA (Signalling Circuit) |
| Impedance | 3 mOhm |
| Mechanical Durability | 10 Mcycles |
| Inrush VA | 30 VA |
| Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
| Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
| Application | Motor Control, Resistive Load |
| Rated Insulation Volts | 600/690V |
| Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
| Signalling Circuit Frequency | Less Than 400 Hz |
| Overvoltage Category | CAT III |
| Hold VA | 4.5 VA |
| Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
| IP Rating | IP22 |
| Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
| Watts Loss | 1.3W |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Switching Voltage | 17 V (Signalling Circuit) |
| Rated Short-Time Withstand Current | 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit) |
| Rated Breaking Capacity | 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V |
| Max. Operating Watts | 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e) |
| Tightening Torque | 0.8 to 1.3 Nm |
| Operating Speed | 3600 cycles per hr |
| Net Weight | 0.18 kg |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Maximum Voltage Rating | 690V AC |
| Mounting Style | DIN Rail, Plate |
| Embedded Surge Suppressor | No |
| Number of Normally Open Main Contacts | 3 |
| Contactor Style | IEC |
| Electrical Operating Durability | 1,300,000, 300,000 |
| Mechanical Operating Durability | 10,000,000 |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Resistive | 20 A |
| Full Load Current - Inductive | 12:00 AM |
| Includes Auxiliary Contacts | Yes |
| Frequency | 50/60 Hz |
| Contactor Application | Resistive load; Motor control |
| Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit |
| Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Control Circuit Type | AC 50/60 Hz |
| Inrush Power in VA | 30 VA (at 68°F (20°C)) |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
| Auxiliary Contacts Type | Instantaneous 1 NO |
| Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
| Rated Operational Current | 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
| Non Overlap Distance | 0.02 in (0.5 mm) |
| Control Circuit Voltage | 110 V AC 50/60 Hz |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Protective Treatment | TC IEC 60068; TC DIN 50016 |
| Utilisation Category | AC-3; AC-3e; AC-1; AC-4 |
| Device Application | Control |
| Maximum Operating Rate | 3600 cyc/h |
| Heat Dissipation | 1.3 W |
| Pole Contact Composition | 3 NO |
Description
The Schneider Electric TeSys K LC1K1210F7 is an IEC magnetic contactor. As a contactor, it electrically opens and closes power circuits. This 3-pole, non-reversing unit operates with a 110V AC coil and uses screw clamp terminals. It is UL Listed and certified to standards including IEC 60947, CSA, and BS 5424.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 110V AC
- Enclosure NEMA Rating: No Enclosure
- Rated Making Capacity: 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
- Impulse Withstand Voltage: 8 kV
- Control Circuit Voltage Limits: Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
- Signalling Circuit Frequency: Less Than 400 Hz
Specifications
| Part Number | LC1K1210F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | No Auxiliary Contacts |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | 6561.68 ft |
| Overall Depth | 2.24 in |
| Overall Width | 1.77 in |
| Overall Height | 2.28 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 1 |
| Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
| Enclosure NEMA Rating | No Enclosure |
| Frame / Series / Class / Code | TeSys |
| Series | TeSys K |
| Reversing | No |
| Rated Making Capacity | 110 A (AC Signalling Circuit), 144 A (AC Power Circuit) |
| Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
| Electrical Durability | 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V) |
| Impulse Withstand Voltage | 8 kV |
| Switching Current | 5 mA (Signalling Circuit) |
| Impedance | 3 mOhm |
| Mechanical Durability | 10 Mcycles |
| Inrush VA | 30 VA |
| Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
| Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
| Application | Motor Control, Resistive Load |
| Rated Insulation Volts | 600/690V |
| Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
| Signalling Circuit Frequency | Less Than 400 Hz |
| Overvoltage Category | CAT III |
| Hold VA | 4.5 VA |
| Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
| IP Rating | IP22 |
| Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
| Watts Loss | 1.3W |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Switching Voltage | 17 V (Signalling Circuit) |
| Rated Short-Time Withstand Current | 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit) |
| Rated Breaking Capacity | 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V |
| Max. Operating Watts | 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e) |
| Tightening Torque | 0.8 to 1.3 Nm |
| Operating Speed | 3600 cycles per hr |
| Net Weight | 0.18 kg |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Maximum Voltage Rating | 690V AC |
| Mounting Style | DIN Rail, Plate |
| Embedded Surge Suppressor | No |
| Number of Normally Open Main Contacts | 3 |
| Contactor Style | IEC |
| Electrical Operating Durability | 1,300,000, 300,000 |
| Mechanical Operating Durability | 10,000,000 |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Resistive | 20 A |
| Full Load Current - Inductive | 12:00 AM |
| Includes Auxiliary Contacts | Yes |
| Frequency | 50/60 Hz |
| Contactor Application | Resistive load; Motor control |
| Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit |
| Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Control Circuit Type | AC 50/60 Hz |
| Inrush Power in VA | 30 VA (at 68°F (20°C)) |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
| Auxiliary Contacts Type | Instantaneous 1 NO |
| Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
| Rated Operational Current | 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
| Non Overlap Distance | 0.02 in (0.5 mm) |
| Control Circuit Voltage | 110 V AC 50/60 Hz |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Protective Treatment | TC IEC 60068; TC DIN 50016 |
| Utilisation Category | AC-3; AC-3e; AC-1; AC-4 |
| Device Application | Control |
| Maximum Operating Rate | 3600 cyc/h |
| Heat Dissipation | 1.3 W |
| Pole Contact Composition | 3 NO |
Description
The Schneider Electric TeSys K LC1K1210F7 is an IEC magnetic contactor. As a contactor, it electrically opens and closes power circuits. This 3-pole, non-reversing unit operates with a 110V AC coil and uses screw clamp terminals. It is UL Listed and certified to standards including IEC 60947, CSA, and BS 5424.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!