LC1K1210F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC Coil

SKU: LC1K1210F7
Your Price:
$180.40
Shipping: $29.95 UPS Ground. Dispatch timing varies by product and supplier.US only. The exact cost is confirmed at checkout.
Add to wishlist
Checkout Secure

Great reasons to buy from us:

  • Image of Quality Guaranteed

    Quality

    Quality Guaranteed
  • Image of Fast Shipping

    Free shipping

    Fast Shipping
  • Image of Great Value

    Fast Shipping

    Great Value
  • Image of Secure Online Ordering

    Free shipping

    Secure Online Ordering
  • Coil Voltage: 110V AC
  • Enclosure NEMA Rating: No Enclosure
  • Rated Making Capacity: 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
  • Impulse Withstand Voltage: 8 kV
  • Control Circuit Voltage Limits: Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
  • Signalling Circuit Frequency: Less Than 400 Hz

Specifications

Part Number LC1K1210F7
Brand Schneider Electric
Auxiliary Contact Form No Auxiliary Contacts
Coil Voltage 110V AC
Number of Poles 3
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Working Height 6561.68 ft
Overall Depth 2.24 in
Overall Width 1.77 in
Overall Height 2.28 in
Item IEC Magnetic Contactor
Number of Auxillary Contacts 1
Standards BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating No Enclosure
Frame / Series / Class / Code TeSys
Series TeSys K
Reversing No
Rated Making Capacity 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
Electrical Durability 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Impulse Withstand Voltage 8 kV
Switching Current 5 mA (Signalling Circuit)
Impedance 3 mOhm
Mechanical Durability 10 Mcycles
Inrush VA 30 VA
Operating Time 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Control Circuit Voltage Limits Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Application Motor Control, Resistive Load
Rated Insulation Volts 600/690V
Shock Resistance 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Signalling Circuit Frequency Less Than 400 Hz
Overvoltage Category CAT III
Hold VA 4.5 VA
Fuse Amps 25 A (Power Circuit), 10 A (Signalling Circuit)
IP Rating IP22
Environmental Attributes Mercury Free, Toxic Heavy Metal Free
Watts Loss 1.3W
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Switching Voltage 17 V (Signalling Circuit)
Rated Short-Time Withstand Current 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Rated Breaking Capacity 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Max. Operating Watts 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e)
Tightening Torque 0.8 to 1.3 Nm
Operating Speed 3600 cycles per hr
Net Weight 0.18 kg
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Maximum Voltage Rating 690V AC
Mounting Style DIN Rail, Plate
Embedded Surge Suppressor No
Number of Normally Open Main Contacts 3
Contactor Style IEC
Electrical Operating Durability 1,300,000, 300,000
Mechanical Operating Durability 10,000,000
NEMA Enclosure Rating No Enclosure
Full Load Current - Resistive 20 A
Full Load Current - Inductive 12:00 AM
Includes Auxiliary Contacts Yes
Frequency 50/60 Hz
Contactor Application Resistive load; Motor control
Conventional Free Air Thermal Current 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Mechanical Robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Operating Altitude 6561.68 ft (2000 m) without derating
Control Circuit Type AC 50/60 Hz
Inrush Power in VA 30 VA (at 68°F (20°C))
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Auxiliary Contacts Type Instantaneous 1 NO
Ambient Air Temperature For Storage -58 to 176°F (-50 to 80°C)
Rated Operational Current 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Non Overlap Distance 0.02 in (0.5 mm)
Control Circuit Voltage 110 V AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protective Treatment TC IEC 60068; TC DIN 50016
Utilisation Category AC-3; AC-3e; AC-1; AC-4
Device Application Control
Maximum Operating Rate 3600 cyc/h
Heat Dissipation 1.3 W
Pole Contact Composition 3 NO

Description

The Schneider Electric TeSys K LC1K1210F7 is an IEC magnetic contactor. As a contactor, it electrically opens and closes power circuits. This 3-pole, non-reversing unit operates with a 110V AC coil and uses screw clamp terminals. It is UL Listed and certified to standards including IEC 60947, CSA, and BS 5424.

Shipping and dispatch

Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.

Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.

Freight shipments

Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.

Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.

Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.

Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

Description

  • Coil Voltage: 110V AC
  • Enclosure NEMA Rating: No Enclosure
  • Rated Making Capacity: 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
  • Impulse Withstand Voltage: 8 kV
  • Control Circuit Voltage Limits: Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
  • Signalling Circuit Frequency: Less Than 400 Hz

Specifications

Part Number LC1K1210F7
Brand Schneider Electric
Auxiliary Contact Form No Auxiliary Contacts
Coil Voltage 110V AC
Number of Poles 3
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Working Height 6561.68 ft
Overall Depth 2.24 in
Overall Width 1.77 in
Overall Height 2.28 in
Item IEC Magnetic Contactor
Number of Auxillary Contacts 1
Standards BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating No Enclosure
Frame / Series / Class / Code TeSys
Series TeSys K
Reversing No
Rated Making Capacity 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
Electrical Durability 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Impulse Withstand Voltage 8 kV
Switching Current 5 mA (Signalling Circuit)
Impedance 3 mOhm
Mechanical Durability 10 Mcycles
Inrush VA 30 VA
Operating Time 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Control Circuit Voltage Limits Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Application Motor Control, Resistive Load
Rated Insulation Volts 600/690V
Shock Resistance 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Signalling Circuit Frequency Less Than 400 Hz
Overvoltage Category CAT III
Hold VA 4.5 VA
Fuse Amps 25 A (Power Circuit), 10 A (Signalling Circuit)
IP Rating IP22
Environmental Attributes Mercury Free, Toxic Heavy Metal Free
Watts Loss 1.3W
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Switching Voltage 17 V (Signalling Circuit)
Rated Short-Time Withstand Current 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Rated Breaking Capacity 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Max. Operating Watts 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e)
Tightening Torque 0.8 to 1.3 Nm
Operating Speed 3600 cycles per hr
Net Weight 0.18 kg
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Maximum Voltage Rating 690V AC
Mounting Style DIN Rail, Plate
Embedded Surge Suppressor No
Number of Normally Open Main Contacts 3
Contactor Style IEC
Electrical Operating Durability 1,300,000, 300,000
Mechanical Operating Durability 10,000,000
NEMA Enclosure Rating No Enclosure
Full Load Current - Resistive 20 A
Full Load Current - Inductive 12:00 AM
Includes Auxiliary Contacts Yes
Frequency 50/60 Hz
Contactor Application Resistive load; Motor control
Conventional Free Air Thermal Current 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Mechanical Robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Operating Altitude 6561.68 ft (2000 m) without derating
Control Circuit Type AC 50/60 Hz
Inrush Power in VA 30 VA (at 68°F (20°C))
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Auxiliary Contacts Type Instantaneous 1 NO
Ambient Air Temperature For Storage -58 to 176°F (-50 to 80°C)
Rated Operational Current 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Non Overlap Distance 0.02 in (0.5 mm)
Control Circuit Voltage 110 V AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protective Treatment TC IEC 60068; TC DIN 50016
Utilisation Category AC-3; AC-3e; AC-1; AC-4
Device Application Control
Maximum Operating Rate 3600 cyc/h
Heat Dissipation 1.3 W
Pole Contact Composition 3 NO

Description

The Schneider Electric TeSys K LC1K1210F7 is an IEC magnetic contactor. As a contactor, it electrically opens and closes power circuits. This 3-pole, non-reversing unit operates with a 110V AC coil and uses screw clamp terminals. It is UL Listed and certified to standards including IEC 60947, CSA, and BS 5424.

Shipping

Shipping and dispatch

Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.

Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.

Freight shipments

Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.

Inspection and Damage:

Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.

Order Cancellations:

All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.

Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.

Why Buy From Us?

Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.

Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.

Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.

Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.

Warranty/Returns

Your purchase is covered by the Manufacturer’s Limited Warranty.

For return/refund information, please visit our Returns & Refunds page.

LC1K1210F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC Coil

LC1K1210F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC Coil

$180.40
Add to wishlist
LC1K1210F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC Coil

LC1K1210F7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 110V AC Coil

Your Price:
$180.40
★

No reviews yet. Be the first to review this product!

Recently viewed products