- Coil Voltage: 24V AC
- HP @ 1 Phase - 230V: 1-1/2
- Enclosure NEMA Rating: No Enclosure
- HP @ 3 Phase - 575V: 5 hp
- Overvoltage Category: CAT III
- Signalling Circuit Frequency: Less Than 400 Hz
Specifications
| Part Number | LC1K0910B7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NO |
| Coil Voltage | 24V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | 6561.68 ft |
| Overall Depth | 1.97 in |
| Overall Width | 1.73 in |
| Overall Height | 1.73 in |
| Item | IEC Miniature Magnetic Contactor |
| Number of Auxillary Contacts | 1 |
| Standards | CSA, UKCA, UL Listed |
| HP @ 1 Phase - 230V | 1-1/2 |
| Enclosure NEMA Rating | No Enclosure |
| HP @ 3 Phase - 575V | 5 hp |
| Frame / Series / Class / Code | TeSys |
| Reversing | No |
| Series | TeSys K |
| Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
| Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
| Mechanical Durability | 10 Mcycles |
| Overvoltage Category | CAT III |
| Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
| Impedance | 3 mOhm |
| Application | Motor Control, Resistive Load |
| Signalling Circuit Frequency | Less Than 400 Hz |
| Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
| Rated Making Capacity | 110 A |
| Operating Speed | 3600 cycles per hr |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
| Hold VA | 4.5 VA |
| Switching Voltage | 17 V (Signalling Circuit) |
| Inrush VA | 30 VA |
| Switching Current | 5 mA (Signalling Circuit) |
| Watts Loss | 1.3W |
| Electrical Durability | 1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V |
| Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V |
| Horsepower @ Three Phase - 240V AC | 3 hp |
| Frequency | 50/60 Hz |
| Horsepower @ Three Phase - 600V AC | 5 hp |
| Full Load Current - Resistive | 20 A |
| Horsepower @ Single Phase - 120V AC | 1/2 hp |
| Contactor Style | IEC |
| Horsepower @ Three Phase - 480V AC | 5 hp |
| Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
| Resistance Properties | Insulation Resistant |
| Horsepower @ Three Phase - 208V AC | 2 hp |
| NEMA Enclosure Rating | No Enclosure |
| Embedded Surge Suppressor | No |
| Full Load Current - Inductive | 9:00 AM |
| Number of Normally Open Main Contacts | 3 |
| Includes Auxiliary Contacts | Yes |
| Maximum Voltage Rating | 690V AC |
| Utilisation Category | AC-3; AC-3e; AC-1; AC-4 |
| Inrush Power in VA | 30 VA (at 68°F (20°C)) |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Contactor Application | Motor control; Resistive load |
| Device Application | Control |
| Control Circuit Type | AC 50/60 Hz |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Maximum Operating Rate | 3600 cyc/h |
| Protective Treatment | TC IEC 60068; TC DIN 50016 |
| Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
| Non Overlap Distance | 0.02 in (0.5 mm) |
| Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit |
| Heat Dissipation | 1.3 W |
| Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
| Control Circuit Voltage | 24 V AC 50/60 Hz |
| Auxiliary Contacts Type | Instantaneous 1 NO |
| Impulse Withstand Voltage | 8 kV |
| Pole Contact Composition | 3 NO |
Description
The Schneider Electric LC1K0910B7 is an IEC miniature magnetic contactor. This type of contactor uses an electromagnetic coil to open and close electrical circuits, enabling motor control. It features a 24V AC coil, three poles, one normally open auxiliary contact, and screw clamp terminals. This unit is UL Listed, CSA certified, and UKCA marked.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 24V AC
- HP @ 1 Phase - 230V: 1-1/2
- Enclosure NEMA Rating: No Enclosure
- HP @ 3 Phase - 575V: 5 hp
- Overvoltage Category: CAT III
- Signalling Circuit Frequency: Less Than 400 Hz
Specifications
| Part Number | LC1K0910B7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NO |
| Coil Voltage | 24V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | 6561.68 ft |
| Overall Depth | 1.97 in |
| Overall Width | 1.73 in |
| Overall Height | 1.73 in |
| Item | IEC Miniature Magnetic Contactor |
| Number of Auxillary Contacts | 1 |
| Standards | CSA, UKCA, UL Listed |
| HP @ 1 Phase - 230V | 1-1/2 |
| Enclosure NEMA Rating | No Enclosure |
| HP @ 3 Phase - 575V | 5 hp |
| Frame / Series / Class / Code | TeSys |
| Reversing | No |
| Series | TeSys K |
| Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
| Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
| Mechanical Durability | 10 Mcycles |
| Overvoltage Category | CAT III |
| Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
| Impedance | 3 mOhm |
| Application | Motor Control, Resistive Load |
| Signalling Circuit Frequency | Less Than 400 Hz |
| Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
| Rated Making Capacity | 110 A |
| Operating Speed | 3600 cycles per hr |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
| Hold VA | 4.5 VA |
| Switching Voltage | 17 V (Signalling Circuit) |
| Inrush VA | 30 VA |
| Switching Current | 5 mA (Signalling Circuit) |
| Watts Loss | 1.3W |
| Electrical Durability | 1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V |
| Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V |
| Horsepower @ Three Phase - 240V AC | 3 hp |
| Frequency | 50/60 Hz |
| Horsepower @ Three Phase - 600V AC | 5 hp |
| Full Load Current - Resistive | 20 A |
| Horsepower @ Single Phase - 120V AC | 1/2 hp |
| Contactor Style | IEC |
| Horsepower @ Three Phase - 480V AC | 5 hp |
| Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
| Resistance Properties | Insulation Resistant |
| Horsepower @ Three Phase - 208V AC | 2 hp |
| NEMA Enclosure Rating | No Enclosure |
| Embedded Surge Suppressor | No |
| Full Load Current - Inductive | 9:00 AM |
| Number of Normally Open Main Contacts | 3 |
| Includes Auxiliary Contacts | Yes |
| Maximum Voltage Rating | 690V AC |
| Utilisation Category | AC-3; AC-3e; AC-1; AC-4 |
| Inrush Power in VA | 30 VA (at 68°F (20°C)) |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Contactor Application | Motor control; Resistive load |
| Device Application | Control |
| Control Circuit Type | AC 50/60 Hz |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Maximum Operating Rate | 3600 cyc/h |
| Protective Treatment | TC IEC 60068; TC DIN 50016 |
| Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
| Non Overlap Distance | 0.02 in (0.5 mm) |
| Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit |
| Heat Dissipation | 1.3 W |
| Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
| Control Circuit Voltage | 24 V AC 50/60 Hz |
| Auxiliary Contacts Type | Instantaneous 1 NO |
| Impulse Withstand Voltage | 8 kV |
| Pole Contact Composition | 3 NO |
Description
The Schneider Electric LC1K0910B7 is an IEC miniature magnetic contactor. This type of contactor uses an electromagnetic coil to open and close electrical circuits, enabling motor control. It features a 24V AC coil, three poles, one normally open auxiliary contact, and screw clamp terminals. This unit is UL Listed, CSA certified, and UKCA marked.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!