- Coil Voltage: 110V AC
- Full Load Amps-Inductive: 6 A
- Enclosure NEMA Rating: No Enclosure
- Hz: 50/60
- Frequency: 50/60 Hz
- Maximum Voltage Rating: 690V AC
Specifications
| Part Number | LC1K0601F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | No Auxiliary Contacts |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Full Load Amps-Inductive | 6 A |
| Reversing Capability | Non-Reversing |
| Width | 1.77 in |
| Depth | 2.24 in |
| Height | 2.28 in |
| Overall Depth | 2.24 in |
| Overall Width | 1.77 in |
| Overall Height | 2.28 in |
| Working Height | 6561.68 ft |
| Item | IEC Magnetic Contactor |
| Terminal Connection Type | Screw Clamp |
| Number of Auxillary Contacts | 1 |
| Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
| Coil Volts | 110 V AC |
| Frame / Series / Class / Code | TeSys |
| Reversing | No |
| Aux. Contact Configuration | None |
| Series | TeSys K |
| Enclosure NEMA Rating | No Enclosure |
| Hz | 50/60 |
| IP Rating | IP22 |
| Resistance Properties | Insulation Resistant |
| Frequency | 50/60 Hz |
| Full Load Current - Inductive | 6 A |
| Maximum Voltage Rating | 690V AC |
| Embedded Surge Suppressor | No |
| Number of Normally Open Main Contacts | 3 |
| NEMA Enclosure Rating | No Enclosure |
| Mechanical Operating Durability | 10,000,000 |
| Electrical Operating Durability | 1,300,000 |
| Contactor Style | IEC |
| Includes Auxiliary Contacts | Yes |
| Mounting Style | DIN Rail, Plate |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Mechanical Durability | 10 Mcycles |
| Max. Operating Watts | 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 2.2 kW (at 380 to 415V AC 50/60 Hz AC-3), 3 kW (at 440V AC 50/60 Hz AC-3), 3 kW (at 480V AC 50/60 Hz AC-3), 3 kW (at 500 to 600V AC 50/60 Hz AC-3), 3 kW (at 660 to 690V AC 50/60 Hz AC-3), 1.5 kW (at 400V AC 50/60 Hz AC-4), 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 2.2 kW(at 380 to 415V AC 50/60 Hz AC-3e), 3 kW (at 440V AC 50/60 Hz AC-3e), 3 kW (at 480V AC 50/60 Hz AC-3e), 3 kW (at 500 to 600V AC 50/60 Hz AC-3e), 3 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Impedance | 3 mOhm |
| Inrush VA | 30 VA |
| Rated Voltage | 690V AC |
| Electrical Connection | Screw Clamp Terminals |
| Net Weight | 0.18 kg |
| Watts Loss | 1.3W |
| Switching Current | 5 mA (Signalling Circuit) |
| Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
| Signalling Circuit Frequency | Less Than 400 Hz |
| Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
| Operating Speed | 3600 cycles per hr |
| Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
| Switching Voltage | 17 V (Signalling Circuit) |
| Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit) |
| Electrical Durability | 1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V) |
| Tightening Torque | 0.8 to 1.3 Nm |
| Mounts On | Plate, Rail |
| Overvoltage Category | CAT III |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Impulse Withstand Voltage | 8 kV |
| Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
| Hold VA | 4.5 VA |
| Application | Motor Control |
| Rated Making Capacity | 110 A |
| Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
| Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
| Rated Insulation Volts | 600/690V |
| Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
| Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V |
Description
The Schneider Electric LC1K0601F7 is a TeSys K IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control and other electrical applications. It features a 110V AC coil, is rated for 6 A inductive full-load amps, and includes one normally closed auxiliary contact with screw clamp terminals. It complies with standards including BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, and VDE 0660.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 110V AC
- Full Load Amps-Inductive: 6 A
- Enclosure NEMA Rating: No Enclosure
- Hz: 50/60
- Frequency: 50/60 Hz
- Maximum Voltage Rating: 690V AC
Specifications
| Part Number | LC1K0601F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | No Auxiliary Contacts |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Full Load Amps-Inductive | 6 A |
| Reversing Capability | Non-Reversing |
| Width | 1.77 in |
| Depth | 2.24 in |
| Height | 2.28 in |
| Overall Depth | 2.24 in |
| Overall Width | 1.77 in |
| Overall Height | 2.28 in |
| Working Height | 6561.68 ft |
| Item | IEC Magnetic Contactor |
| Terminal Connection Type | Screw Clamp |
| Number of Auxillary Contacts | 1 |
| Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
| Coil Volts | 110 V AC |
| Frame / Series / Class / Code | TeSys |
| Reversing | No |
| Aux. Contact Configuration | None |
| Series | TeSys K |
| Enclosure NEMA Rating | No Enclosure |
| Hz | 50/60 |
| IP Rating | IP22 |
| Resistance Properties | Insulation Resistant |
| Frequency | 50/60 Hz |
| Full Load Current - Inductive | 6 A |
| Maximum Voltage Rating | 690V AC |
| Embedded Surge Suppressor | No |
| Number of Normally Open Main Contacts | 3 |
| NEMA Enclosure Rating | No Enclosure |
| Mechanical Operating Durability | 10,000,000 |
| Electrical Operating Durability | 1,300,000 |
| Contactor Style | IEC |
| Includes Auxiliary Contacts | Yes |
| Mounting Style | DIN Rail, Plate |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Mechanical Durability | 10 Mcycles |
| Max. Operating Watts | 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 2.2 kW (at 380 to 415V AC 50/60 Hz AC-3), 3 kW (at 440V AC 50/60 Hz AC-3), 3 kW (at 480V AC 50/60 Hz AC-3), 3 kW (at 500 to 600V AC 50/60 Hz AC-3), 3 kW (at 660 to 690V AC 50/60 Hz AC-3), 1.5 kW (at 400V AC 50/60 Hz AC-4), 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 2.2 kW(at 380 to 415V AC 50/60 Hz AC-3e), 3 kW (at 440V AC 50/60 Hz AC-3e), 3 kW (at 480V AC 50/60 Hz AC-3e), 3 kW (at 500 to 600V AC 50/60 Hz AC-3e), 3 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Impedance | 3 mOhm |
| Inrush VA | 30 VA |
| Rated Voltage | 690V AC |
| Electrical Connection | Screw Clamp Terminals |
| Net Weight | 0.18 kg |
| Watts Loss | 1.3W |
| Switching Current | 5 mA (Signalling Circuit) |
| Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
| Signalling Circuit Frequency | Less Than 400 Hz |
| Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
| Operating Speed | 3600 cycles per hr |
| Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
| Switching Voltage | 17 V (Signalling Circuit) |
| Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit) |
| Electrical Durability | 1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V) |
| Tightening Torque | 0.8 to 1.3 Nm |
| Mounts On | Plate, Rail |
| Overvoltage Category | CAT III |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Impulse Withstand Voltage | 8 kV |
| Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
| Hold VA | 4.5 VA |
| Application | Motor Control |
| Rated Making Capacity | 110 A |
| Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
| Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
| Rated Insulation Volts | 600/690V |
| Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
| Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V |
Description
The Schneider Electric LC1K0601F7 is a TeSys K IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control and other electrical applications. It features a 110V AC coil, is rated for 6 A inductive full-load amps, and includes one normally closed auxiliary contact with screw clamp terminals. It complies with standards including BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, and VDE 0660.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!