- Coil Voltage: 240V AC
- HP @ 3 Phase - 575V: 30 hp
- HP @ 1 Phase - 230V: 5
- Enclosure NEMA Rating: No Enclosure
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Signalling Circuit Frequency: 25 to 400 Hz
Specifications
| Part Number | LC1D40AU7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 240V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 2.17 in |
| Overall Depth | 4.72 in |
| Overall Height | 4.8 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed |
| HP @ 3 Phase - 575V | 30 hp |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| HP @ 1 Phase - 230V | 5 |
| Enclosure NEMA Rating | No Enclosure |
| Includes | Everlink Power Connections |
| Series | TeSys Deca |
| Operating Speed | 3600 cycles per hr |
| Switching Current | 5 mA (Signalling Circuit) |
| Rated Short-Time Withstand Current | 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| IP Rating | IP20 |
| Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
| Fire Rating | UL 94 V1 |
| Non-Overlap Time | 1.5 ms |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Features | Without Built-In Suppressor Module |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Application | Motor Control, Resistive Load |
| Rated Insulation Volts | 600/690V |
| Switching Voltage | 17 V (Signalling Circuit) |
| Net Weight | 0.85 kg |
| Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
| Overvoltage Category | CAT III |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
| Electrical Durability | 1.4 Mcycles (60 A, AC-1, Less than 440 V); 1.5 Mcycles (40 A, AC-3, Less than 440 V); 1.5 Mcycles (40 A, AC-3e, Less than 440 V) |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Includes Protective Cover | Yes |
| Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
| Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
| Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Impedance | 1.5 mOhm |
| Mechanical Durability | 6 Mcycles |
| Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
| Watts Loss | 4 to 5W |
| Impulse Withstand Voltage | 6 kV |
| Rated Breaking Capacity | 800 A @ 440V |
| Includes Auxiliary Contacts | Yes |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Resistive | 60 A |
| Maximum Voltage Rating | 690V AC |
| Horsepower @ Single Phase - 120V AC | 3 hp |
| Horsepower @ Three Phase - 240V AC | 10 hp |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Embedded Surge Suppressor | No |
| Phase | Three |
| Contactor Style | IEC |
| Mechanical Operating Durability | 6,000,000 |
| Maximum Operating Temperature | 140 Degrees F |
| Horsepower @ Three Phase - 480V AC | 30 hp |
| Horsepower @ Single Phase - 240V AC | 5 hp |
| Mounting Style | DIN Rail, Plate |
| Horsepower @ Three Phase - 208V AC | 10 hp |
| Minimum Operating Temperature | -40 Degrees F |
| Horsepower @ Three Phase - 600V AC | 30 hp |
| Full Load Current - Inductive | 40 A |
| Number of Normally Open Main Contacts | 3 |
| Electrical Operating Durability | 1,400,000, 1,500,000 |
| Frequency | 50/60 Hz |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D40AU7 is a TeSys IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control and other electrical applications. It operates with a 240V AC coil voltage, is rated for 40 amps across three poles, and supports 30 hp at 575V three-phase or 5 hp at 230V single-phase. It meets CCC, CSA, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, and UL Listed standards.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 240V AC
- HP @ 3 Phase - 575V: 30 hp
- HP @ 1 Phase - 230V: 5
- Enclosure NEMA Rating: No Enclosure
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Signalling Circuit Frequency: 25 to 400 Hz
Specifications
| Part Number | LC1D40AU7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 240V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 2.17 in |
| Overall Depth | 4.72 in |
| Overall Height | 4.8 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed |
| HP @ 3 Phase - 575V | 30 hp |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| HP @ 1 Phase - 230V | 5 |
| Enclosure NEMA Rating | No Enclosure |
| Includes | Everlink Power Connections |
| Series | TeSys Deca |
| Operating Speed | 3600 cycles per hr |
| Switching Current | 5 mA (Signalling Circuit) |
| Rated Short-Time Withstand Current | 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| IP Rating | IP20 |
| Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
| Fire Rating | UL 94 V1 |
| Non-Overlap Time | 1.5 ms |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Features | Without Built-In Suppressor Module |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Application | Motor Control, Resistive Load |
| Rated Insulation Volts | 600/690V |
| Switching Voltage | 17 V (Signalling Circuit) |
| Net Weight | 0.85 kg |
| Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
| Overvoltage Category | CAT III |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
| Electrical Durability | 1.4 Mcycles (60 A, AC-1, Less than 440 V); 1.5 Mcycles (40 A, AC-3, Less than 440 V); 1.5 Mcycles (40 A, AC-3e, Less than 440 V) |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Includes Protective Cover | Yes |
| Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
| Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
| Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Impedance | 1.5 mOhm |
| Mechanical Durability | 6 Mcycles |
| Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
| Watts Loss | 4 to 5W |
| Impulse Withstand Voltage | 6 kV |
| Rated Breaking Capacity | 800 A @ 440V |
| Includes Auxiliary Contacts | Yes |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Resistive | 60 A |
| Maximum Voltage Rating | 690V AC |
| Horsepower @ Single Phase - 120V AC | 3 hp |
| Horsepower @ Three Phase - 240V AC | 10 hp |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Embedded Surge Suppressor | No |
| Phase | Three |
| Contactor Style | IEC |
| Mechanical Operating Durability | 6,000,000 |
| Maximum Operating Temperature | 140 Degrees F |
| Horsepower @ Three Phase - 480V AC | 30 hp |
| Horsepower @ Single Phase - 240V AC | 5 hp |
| Mounting Style | DIN Rail, Plate |
| Horsepower @ Three Phase - 208V AC | 10 hp |
| Minimum Operating Temperature | -40 Degrees F |
| Horsepower @ Three Phase - 600V AC | 30 hp |
| Full Load Current - Inductive | 40 A |
| Number of Normally Open Main Contacts | 3 |
| Electrical Operating Durability | 1,400,000, 1,500,000 |
| Frequency | 50/60 Hz |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D40AU7 is a TeSys IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control and other electrical applications. It operates with a 240V AC coil voltage, is rated for 40 amps across three poles, and supports 30 hp at 575V three-phase or 5 hp at 230V single-phase. It meets CCC, CSA, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, and UL Listed standards.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!