- Coil Voltage: 110V AC
- HP @ 3 Phase - 575V: 30 hp
- Overvoltage Category: CAT III
- Fuse Amps: 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Rated Breaking Capacity: 800 A @ 440V
Specifications
| Part Number | LC1D40AF7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 2.17 in |
| Overall Height | 4.8 in |
| Overall Depth | 4.72 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 1 |
| Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40:Annex JJ, UL 60947-4-1 |
| Includes | Everlink Power Connections |
| Series | TeSys |
| HP @ 3 Phase - 575V | 30 hp |
| Features | Without Built-In Suppressor Module |
| Overvoltage Category | CAT III |
| Includes Protective Cover | Yes |
| Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Switching Current | 5 mA (Signalling Circuit) |
| Electrical Durability | 1.4 Mcycles (60 A, AC-1, Less than 440 V); 1.5 Mcycles (40 A, AC-3, Less than 440 V); 1.5 Mcycles (40 A, AC-3e, Less than 440 V) |
| Operating Speed | 3600 cycles per hr |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
| Rated Breaking Capacity | 800 A @ 440V |
| Switching Voltage | 17 V (Signalling Circuit) |
| Impedance | 1.5 mOhm |
| Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Rated Short-Time Withstand Current | 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Watts Loss | 4 to 5W |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Net Weight | 0.85 kg |
| Impulse Withstand Voltage | 6 kV |
| IP Rating | IP20 |
| Rated Insulation Volts | 600/690V |
| Non-Overlap Time | 1.5 ms |
| Fire Rating | UL 94 V1 |
| Application | Motor Control, Resistive Load |
| Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
| Mechanical Durability | 6 Mcycles |
| Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
| Pole Contact Composition | 3 NO |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Pollution Degree | 3 |
| Contact Compatibility | M2 |
| Rated Operational Current | 60 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
| Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
| Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
| Heat Dissipation | 4 to 5 W at 50/60 Hz |
| Control Circuit Type | AC 50/60 Hz standard |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms) |
| Contactor Application | Resistive load; Motor control |
| Utilisation Category | AC-4; AC-1; AC-3; AC-3e |
| Protective Treatment | THIEC 60068-2-30 |
| Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
| Inrush Power in VA | 140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
| Control Circuit Voltage | 110 V AC 50/60 Hz |
| Protective Cover | With |
| Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit; 60 A (at 140°F (60°C)) for power circuit |
| Power Dissipation Per Pole | 2.4 W AC-3; 5.4 W AC-1; 2.4 W AC-3e |
| Climatic Withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
| Horsepower @ Three Phase - 480V AC | 30 hp |
| Horsepower @ Three Phase - 240V AC | 10 hp |
| Full Load Current - Inductive | 40 A |
| Full Load Current - Resistive | 60 A |
| Horsepower @ Three Phase - 208V AC | 10 hp |
| Horsepower @ Single Phase - 240V AC | 5 hp |
| Horsepower @ Three Phase - 600V AC | 30 hp |
| Maximum Operating Temperature | 140 Degrees F |
| Maximum Voltage Rating | 690V AC |
| Electrical Operating Durability | 1,500,000 |
| Frequency | 50/60 Hz |
| Minimum Operating Temperature | -40 Degrees F |
| Includes Auxiliary Contacts | Yes |
| Mounting Style | Plate, DIN Rail |
| Number of Normally Open Main Contacts | 3 |
| Response Time | 12 to 26 msec (Closing), 4 to 19 msec (Opening) |
| Contactor Style | IEC |
| Phase | Three |
| Mechanical Operating Durability | 6,000,000 |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Description
The Schneider Electric LC1D40AF7 is a TeSys series IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It features a 110V AC coil, screw clamp terminals, and Everlink power connections, and is rated for 40 amps and 30 hp at 575V three-phase. It complies with standards including IEC 60947-4-1 and UL 60947-4-1.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 110V AC
- HP @ 3 Phase - 575V: 30 hp
- Overvoltage Category: CAT III
- Fuse Amps: 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Rated Breaking Capacity: 800 A @ 440V
Specifications
| Part Number | LC1D40AF7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 2.17 in |
| Overall Height | 4.8 in |
| Overall Depth | 4.72 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 1 |
| Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40:Annex JJ, UL 60947-4-1 |
| Includes | Everlink Power Connections |
| Series | TeSys |
| HP @ 3 Phase - 575V | 30 hp |
| Features | Without Built-In Suppressor Module |
| Overvoltage Category | CAT III |
| Includes Protective Cover | Yes |
| Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Switching Current | 5 mA (Signalling Circuit) |
| Electrical Durability | 1.4 Mcycles (60 A, AC-1, Less than 440 V); 1.5 Mcycles (40 A, AC-3, Less than 440 V); 1.5 Mcycles (40 A, AC-3e, Less than 440 V) |
| Operating Speed | 3600 cycles per hr |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
| Rated Breaking Capacity | 800 A @ 440V |
| Switching Voltage | 17 V (Signalling Circuit) |
| Impedance | 1.5 mOhm |
| Max. Operating Watts | 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Rated Short-Time Withstand Current | 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Watts Loss | 4 to 5W |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Net Weight | 0.85 kg |
| Impulse Withstand Voltage | 6 kV |
| IP Rating | IP20 |
| Rated Insulation Volts | 600/690V |
| Non-Overlap Time | 1.5 ms |
| Fire Rating | UL 94 V1 |
| Application | Motor Control, Resistive Load |
| Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
| Mechanical Durability | 6 Mcycles |
| Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
| Pole Contact Composition | 3 NO |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Pollution Degree | 3 |
| Contact Compatibility | M2 |
| Rated Operational Current | 60 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
| Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
| Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
| Heat Dissipation | 4 to 5 W at 50/60 Hz |
| Control Circuit Type | AC 50/60 Hz standard |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms) |
| Contactor Application | Resistive load; Motor control |
| Utilisation Category | AC-4; AC-1; AC-3; AC-3e |
| Protective Treatment | THIEC 60068-2-30 |
| Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
| Inrush Power in VA | 140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
| Control Circuit Voltage | 110 V AC 50/60 Hz |
| Protective Cover | With |
| Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit; 60 A (at 140°F (60°C)) for power circuit |
| Power Dissipation Per Pole | 2.4 W AC-3; 5.4 W AC-1; 2.4 W AC-3e |
| Climatic Withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
| Horsepower @ Three Phase - 480V AC | 30 hp |
| Horsepower @ Three Phase - 240V AC | 10 hp |
| Full Load Current - Inductive | 40 A |
| Full Load Current - Resistive | 60 A |
| Horsepower @ Three Phase - 208V AC | 10 hp |
| Horsepower @ Single Phase - 240V AC | 5 hp |
| Horsepower @ Three Phase - 600V AC | 30 hp |
| Maximum Operating Temperature | 140 Degrees F |
| Maximum Voltage Rating | 690V AC |
| Electrical Operating Durability | 1,500,000 |
| Frequency | 50/60 Hz |
| Minimum Operating Temperature | -40 Degrees F |
| Includes Auxiliary Contacts | Yes |
| Mounting Style | Plate, DIN Rail |
| Number of Normally Open Main Contacts | 3 |
| Response Time | 12 to 26 msec (Closing), 4 to 19 msec (Opening) |
| Contactor Style | IEC |
| Phase | Three |
| Mechanical Operating Durability | 6,000,000 |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Description
The Schneider Electric LC1D40AF7 is a TeSys series IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It features a 110V AC coil, screw clamp terminals, and Everlink power connections, and is rated for 40 amps and 30 hp at 575V three-phase. It complies with standards including IEC 60947-4-1 and UL 60947-4-1.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!