Great reasons to buy from us:
-
Quality
Quality Guaranteed -
Free shipping
Fast Shipping -
Fast Shipping
Great Value -
Free shipping
Secure Online Ordering
- Coil Voltage: 24V AC
- HP @ 3 Phase - 575V: 30 hp
- HP @ 1 Phase - 230V: 5
- Enclosure NEMA Rating: No Enclosure
- Impulse Withstand Voltage: 6 kV
- Rated Breaking Capacity: 550 A @ 440V
Specifications
| Part Number | LC1D32B7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 24V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Height | 3.35 in |
| Overall Width | 1.77 in |
| Overall Depth | 3.62 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| HP @ 3 Phase - 575V | 30 hp |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| HP @ 1 Phase - 230V | 5 |
| Enclosure NEMA Rating | No Enclosure |
| Series | TeSys Deca |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Rated Insulation Volts | 600/690V |
| Impulse Withstand Voltage | 6 kV |
| Net Weight | 0.375 kg |
| Fire Rating | UL 94 V1 |
| Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Includes Protective Cover | Yes |
| Rated Short-Time Withstand Current | 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Rated Breaking Capacity | 550 A @ 440V |
| Impedance | 2 mOhm |
| Switching Current | 5 mA (Signalling Circuit) |
| Switching Voltage | 17 V (Signalling Circuit) |
| Overvoltage Category | CAT III |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Electrical Durability | 1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
| Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit) |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
| Operating Speed | 3600 cycles per hr |
| Mechanical Durability | 15 Mcycles |
| Features | Without Built-In Suppressor Module |
| Inrush VA | 70 VA |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| IP Rating | IP20 |
| Non-Overlap Time | 1.5 ms |
| Application | Motor Control, Resistive Load |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Watts Loss | 2 to 3W |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit) |
| Max. Operating Watts | 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Horsepower @ Single Phase - 240V AC | 5 hp |
| Number of Normally Open Main Contacts | 3 |
| Full Load Current - Resistive | 50 A |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Maximum Voltage Rating | 690V AC |
| Horsepower @ Three Phase - 240V AC | 10 hp |
| Full Load Current - Inductive | 32 A |
| Electrical Operating Durability | 1,400,000, 1,650,000 |
| Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
| Contactor Style | IEC |
| Mechanical Operating Durability | 15,000,000 |
| Minimum Operating Temperature | -40 Degrees F |
| Includes Auxiliary Contacts | Yes |
| Frequency | 50/60 Hz |
| Maximum Operating Temperature | 140 Degrees F |
| Phase | Three |
| Horsepower @ Three Phase - 600V AC | 30 hp |
| Horsepower @ Single Phase - 120V AC | 2 hp |
| NEMA Enclosure Rating | No Enclosure |
| Horsepower @ Three Phase - 480V AC | 20 hp |
| Mounting Style | DIN Rail, Plate |
| Embedded Surge Suppressor | No |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D32B7 is a TeSys IEC magnetic contactor with a 24V AC coil and screw clamp terminals. This contactor opens and closes power circuits in response to a control signal, switching 32A across three poles with one normally open and one normally closed auxiliary contact. It is rated for 30 hp at 575V three-phase and 5 hp at 230V single-phase, and complies with standards including IEC 60947-4-1, UL 508, and CSA.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 24V AC
- HP @ 3 Phase - 575V: 30 hp
- HP @ 1 Phase - 230V: 5
- Enclosure NEMA Rating: No Enclosure
- Impulse Withstand Voltage: 6 kV
- Rated Breaking Capacity: 550 A @ 440V
Specifications
| Part Number | LC1D32B7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 24V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Height | 3.35 in |
| Overall Width | 1.77 in |
| Overall Depth | 3.62 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| HP @ 3 Phase - 575V | 30 hp |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| HP @ 1 Phase - 230V | 5 |
| Enclosure NEMA Rating | No Enclosure |
| Series | TeSys Deca |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Rated Insulation Volts | 600/690V |
| Impulse Withstand Voltage | 6 kV |
| Net Weight | 0.375 kg |
| Fire Rating | UL 94 V1 |
| Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Includes Protective Cover | Yes |
| Rated Short-Time Withstand Current | 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Rated Breaking Capacity | 550 A @ 440V |
| Impedance | 2 mOhm |
| Switching Current | 5 mA (Signalling Circuit) |
| Switching Voltage | 17 V (Signalling Circuit) |
| Overvoltage Category | CAT III |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Electrical Durability | 1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
| Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit) |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
| Operating Speed | 3600 cycles per hr |
| Mechanical Durability | 15 Mcycles |
| Features | Without Built-In Suppressor Module |
| Inrush VA | 70 VA |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| IP Rating | IP20 |
| Non-Overlap Time | 1.5 ms |
| Application | Motor Control, Resistive Load |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Watts Loss | 2 to 3W |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit) |
| Max. Operating Watts | 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Horsepower @ Single Phase - 240V AC | 5 hp |
| Number of Normally Open Main Contacts | 3 |
| Full Load Current - Resistive | 50 A |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Maximum Voltage Rating | 690V AC |
| Horsepower @ Three Phase - 240V AC | 10 hp |
| Full Load Current - Inductive | 32 A |
| Electrical Operating Durability | 1,400,000, 1,650,000 |
| Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
| Contactor Style | IEC |
| Mechanical Operating Durability | 15,000,000 |
| Minimum Operating Temperature | -40 Degrees F |
| Includes Auxiliary Contacts | Yes |
| Frequency | 50/60 Hz |
| Maximum Operating Temperature | 140 Degrees F |
| Phase | Three |
| Horsepower @ Three Phase - 600V AC | 30 hp |
| Horsepower @ Single Phase - 120V AC | 2 hp |
| NEMA Enclosure Rating | No Enclosure |
| Horsepower @ Three Phase - 480V AC | 20 hp |
| Mounting Style | DIN Rail, Plate |
| Embedded Surge Suppressor | No |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D32B7 is a TeSys IEC magnetic contactor with a 24V AC coil and screw clamp terminals. This contactor opens and closes power circuits in response to a control signal, switching 32A across three poles with one normally open and one normally closed auxiliary contact. It is rated for 30 hp at 575V three-phase and 5 hp at 230V single-phase, and complies with standards including IEC 60947-4-1, UL 508, and CSA.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!