- Coil Voltage: 240V AC
- HP @ 1 Phase - 230V: 3
- Enclosure NEMA Rating: No Enclosure
- HP @ 3 Phase - 575V: 20 hp
- Signalling Circuit Frequency: 25 to 400 Hz
- Impulse Withstand Voltage: 6 kV
Specifications
| Part Number | LC1D25U7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 240V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Height | 3.35 in |
| Overall Depth | 3.62 in |
| Overall Width | 1.77 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| HP @ 1 Phase - 230V | 3 |
| Frame / Series / Class / Code | TeSys |
| Enclosure NEMA Rating | No Enclosure |
| Reversing | No |
| HP @ 3 Phase - 575V | 20 hp |
| Series | TeSys Deca |
| IP Rating | IP20 |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Impulse Withstand Voltage | 6 kV |
| Fire Rating | UL 94 V1 |
| Inrush VA | 70 VA |
| Features | Without Built-In Suppressor Module |
| Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Operating Speed | 3600 cycles per hr |
| Rated Insulation Volts | 600/690V |
| Application | Motor Control, Resistive Load |
| Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
| Mechanical Durability | 15 Mcycles |
| Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Watts Loss | 2 to 3W |
| Non-Overlap Time | 1.5 ms |
| Electrical Durability | 1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
| Switching Current | 5 mA (Signalling Circuit) |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| Includes Protective Cover | Yes |
| Switching Voltage | 17 V (Signalling Circuit) |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Net Weight | 0.37 kg |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Rated Breaking Capacity | 450 A @ 440V |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
| Rated Short-Time Withstand Current | 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Impedance | 2 mOhm |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Overvoltage Category | CAT III |
| Mounting Style | DIN Rail, Plate |
| Electrical Operating Durability | 1,400,000, 1,650,000 |
| Frequency | 50/60 Hz |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Inductive | 25 A |
| Phase | Three |
| Includes Auxiliary Contacts | Yes |
| Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Mechanical Operating Durability | 15,000,000 |
| Contactor Style | IEC |
| Horsepower @ Three Phase - 480V AC | 15 hp |
| Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
| Maximum Voltage Rating | 690V AC |
| Number of Normally Open Main Contacts | 3 |
| Horsepower @ Single Phase - 240V AC | 3 hp |
| Maximum Operating Temperature | 140 Degrees F |
| Horsepower @ Three Phase - 600V AC | 20 hp |
| Full Load Current - Resistive | 40 A |
| Minimum Operating Temperature | -40 Degrees F |
| Horsepower @ Single Phase - 120V AC | 2 hp |
| Embedded Surge Suppressor | No |
| Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit |
| Protective Treatment | THIEC 60068-2-30 |
| Pollution Degree | 3 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Heat Dissipation | 2 to 3 W at 50/60 Hz |
| Control Circuit Voltage | 240 V AC 50/60 Hz |
| Protective Cover | With |
| Contactor Application | Motor control; Resistive load |
| Control Circuit Type | AC 50/60 Hz |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Pole Contact Composition | 3 NO |
| Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
| Utilisation Category | AC-3; AC-1; AC-3e |
| Climatic Withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
| Power Dissipation Per Pole | 3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e |
| Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
| Contact Compatibility | M2 |
| Rated Operational Current | 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms) |
| Compatibility Code | LC1D |
| Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
| Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
| Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Description
The Schneider Electric LC1D25U7 is a TeSys IEC magnetic contactor with a 240V AC coil and screw clamp terminals. This contactor opens and closes power circuits in response to a control signal. It is a 3-pole, non-reversing unit rated for 25A and 3 HP at 230V single-phase, and it complies with standards including UL, CSA, IEC, and CCC.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 240V AC
- HP @ 1 Phase - 230V: 3
- Enclosure NEMA Rating: No Enclosure
- HP @ 3 Phase - 575V: 20 hp
- Signalling Circuit Frequency: 25 to 400 Hz
- Impulse Withstand Voltage: 6 kV
Specifications
| Part Number | LC1D25U7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 240V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Height | 3.35 in |
| Overall Depth | 3.62 in |
| Overall Width | 1.77 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| HP @ 1 Phase - 230V | 3 |
| Frame / Series / Class / Code | TeSys |
| Enclosure NEMA Rating | No Enclosure |
| Reversing | No |
| HP @ 3 Phase - 575V | 20 hp |
| Series | TeSys Deca |
| IP Rating | IP20 |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Impulse Withstand Voltage | 6 kV |
| Fire Rating | UL 94 V1 |
| Inrush VA | 70 VA |
| Features | Without Built-In Suppressor Module |
| Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
| Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Operating Speed | 3600 cycles per hr |
| Rated Insulation Volts | 600/690V |
| Application | Motor Control, Resistive Load |
| Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
| Mechanical Durability | 15 Mcycles |
| Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Watts Loss | 2 to 3W |
| Non-Overlap Time | 1.5 ms |
| Electrical Durability | 1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
| Switching Current | 5 mA (Signalling Circuit) |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| Includes Protective Cover | Yes |
| Switching Voltage | 17 V (Signalling Circuit) |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Net Weight | 0.37 kg |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Rated Breaking Capacity | 450 A @ 440V |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
| Rated Short-Time Withstand Current | 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Impedance | 2 mOhm |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Overvoltage Category | CAT III |
| Mounting Style | DIN Rail, Plate |
| Electrical Operating Durability | 1,400,000, 1,650,000 |
| Frequency | 50/60 Hz |
| NEMA Enclosure Rating | No Enclosure |
| Full Load Current - Inductive | 25 A |
| Phase | Three |
| Includes Auxiliary Contacts | Yes |
| Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Mechanical Operating Durability | 15,000,000 |
| Contactor Style | IEC |
| Horsepower @ Three Phase - 480V AC | 15 hp |
| Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
| Maximum Voltage Rating | 690V AC |
| Number of Normally Open Main Contacts | 3 |
| Horsepower @ Single Phase - 240V AC | 3 hp |
| Maximum Operating Temperature | 140 Degrees F |
| Horsepower @ Three Phase - 600V AC | 20 hp |
| Full Load Current - Resistive | 40 A |
| Minimum Operating Temperature | -40 Degrees F |
| Horsepower @ Single Phase - 120V AC | 2 hp |
| Embedded Surge Suppressor | No |
| Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit |
| Protective Treatment | THIEC 60068-2-30 |
| Pollution Degree | 3 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Heat Dissipation | 2 to 3 W at 50/60 Hz |
| Control Circuit Voltage | 240 V AC 50/60 Hz |
| Protective Cover | With |
| Contactor Application | Motor control; Resistive load |
| Control Circuit Type | AC 50/60 Hz |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Pole Contact Composition | 3 NO |
| Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
| Utilisation Category | AC-3; AC-1; AC-3e |
| Climatic Withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
| Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
| Power Dissipation Per Pole | 3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e |
| Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
| Contact Compatibility | M2 |
| Rated Operational Current | 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms) |
| Compatibility Code | LC1D |
| Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
| Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
| Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Description
The Schneider Electric LC1D25U7 is a TeSys IEC magnetic contactor with a 240V AC coil and screw clamp terminals. This contactor opens and closes power circuits in response to a control signal. It is a 3-pole, non-reversing unit rated for 25A and 3 HP at 230V single-phase, and it complies with standards including UL, CSA, IEC, and CCC.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!