Great reasons to buy from us:
-
Quality
Quality Guaranteed -
Free shipping
Fast Shipping -
Fast Shipping
Great Value -
Free shipping
Secure Online Ordering
- Coil Voltage: 120V AC
- Enclosure NEMA Rating: No Enclosure
- HP @ 3 Phase - 575V: 15 hp
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Switching Voltage: 17 V (Signalling Circuit)
- Rated Making Capacity: 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Specifications
| Part Number | LC1D18G7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 120V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 1.77 in |
| Overall Depth | 3.39 in |
| Overall Height | 3.03 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| Enclosure NEMA Rating | No Enclosure |
| HP @ 3 Phase - 575V | 15 hp |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| Series | TeSys Deca |
| Max. Operating Watts | 4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Features | Without Built-In Suppressor Module |
| Electrical Durability | 1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V); 1.65 Mcycles (18 A, AC-3e, Less than 440 V) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Rated Insulation Volts | 600/690V |
| Net Weight | 0.33 kg |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Switching Voltage | 17 V (Signalling Circuit) |
| Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
| Fire Rating | UL 94 V1 |
| Impedance | 2.5 mOhm |
| Watts Loss | 2 to 3W |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| Overvoltage Category | CAT III |
| Rated Short-Time Withstand Current | 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Inrush VA | 70 VA |
| Operating Speed | 3600 cycles per hr |
| Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
| Application | Motor Control, Resistive Load |
| Non-Overlap Time | 1.5 ms |
| Mechanical Durability | 15 Mcycles |
| Tightening Torque | 1.7 Nm |
| Includes Protective Cover | Yes |
| Signalling Circuit Frequency | 25 to 400 Hz |
| IP Rating | IP20 |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Impulse Withstand Voltage | 6 kV |
| Rated Breaking Capacity | 300 A @ 440V |
| Switching Current | 5 mA (Signalling Circuit) |
| Mechanical Operating Durability | 15,000,000 |
| Frequency | 50/60 Hz |
| Electrical Operating Durability | 1,000,000, 1,650,000 |
| Maximum Operating Temperature | 140 Degrees F |
| Full Load Current - Inductive | 18 A |
| NEMA Enclosure Rating | No Enclosure |
| Horsepower @ Single Phase - 120V AC | 1 hp |
| Phase | Three |
| Horsepower @ Three Phase - 208V AC | 5 hp |
| Mounting Style | DIN Rail, Plate |
| Includes Auxiliary Contacts | Yes |
| Horsepower @ Three Phase - 600V AC | 15 hp |
| Contactor Style | IEC |
| Number of Normally Open Main Contacts | 3 |
| Horsepower @ Three Phase - 480V AC | 10 hp |
| Horsepower @ Three Phase - 240V AC | 5 hp |
| Maximum Voltage Rating | 690V AC |
| Minimum Operating Temperature | -40 Degrees F |
| Embedded Surge Suppressor | No |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Horsepower @ Single Phase - 240V AC | 3 hp |
| Full Load Current - Resistive | 32 A |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D18G7 is a TeSys IEC magnetic contactor with a 120V AC coil and screw clamp terminals. This contactor switches power to a load by opening and closing its main contacts when the coil is energized or de-energized. It is rated for 15 hp at 575V three-phase and carries certifications including UL, CSA, IEC, and CCC.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 120V AC
- Enclosure NEMA Rating: No Enclosure
- HP @ 3 Phase - 575V: 15 hp
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Switching Voltage: 17 V (Signalling Circuit)
- Rated Making Capacity: 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Specifications
| Part Number | LC1D18G7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 120V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 1.77 in |
| Overall Depth | 3.39 in |
| Overall Height | 3.03 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| Enclosure NEMA Rating | No Enclosure |
| HP @ 3 Phase - 575V | 15 hp |
| Reversing | No |
| Frame / Series / Class / Code | TeSys |
| Series | TeSys Deca |
| Max. Operating Watts | 4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Features | Without Built-In Suppressor Module |
| Electrical Durability | 1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V); 1.65 Mcycles (18 A, AC-3e, Less than 440 V) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Rated Insulation Volts | 600/690V |
| Net Weight | 0.33 kg |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Switching Voltage | 17 V (Signalling Circuit) |
| Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
| Fire Rating | UL 94 V1 |
| Impedance | 2.5 mOhm |
| Watts Loss | 2 to 3W |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| Overvoltage Category | CAT III |
| Rated Short-Time Withstand Current | 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Inrush VA | 70 VA |
| Operating Speed | 3600 cycles per hr |
| Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
| Application | Motor Control, Resistive Load |
| Non-Overlap Time | 1.5 ms |
| Mechanical Durability | 15 Mcycles |
| Tightening Torque | 1.7 Nm |
| Includes Protective Cover | Yes |
| Signalling Circuit Frequency | 25 to 400 Hz |
| IP Rating | IP20 |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Impulse Withstand Voltage | 6 kV |
| Rated Breaking Capacity | 300 A @ 440V |
| Switching Current | 5 mA (Signalling Circuit) |
| Mechanical Operating Durability | 15,000,000 |
| Frequency | 50/60 Hz |
| Electrical Operating Durability | 1,000,000, 1,650,000 |
| Maximum Operating Temperature | 140 Degrees F |
| Full Load Current - Inductive | 18 A |
| NEMA Enclosure Rating | No Enclosure |
| Horsepower @ Single Phase - 120V AC | 1 hp |
| Phase | Three |
| Horsepower @ Three Phase - 208V AC | 5 hp |
| Mounting Style | DIN Rail, Plate |
| Includes Auxiliary Contacts | Yes |
| Horsepower @ Three Phase - 600V AC | 15 hp |
| Contactor Style | IEC |
| Number of Normally Open Main Contacts | 3 |
| Horsepower @ Three Phase - 480V AC | 10 hp |
| Horsepower @ Three Phase - 240V AC | 5 hp |
| Maximum Voltage Rating | 690V AC |
| Minimum Operating Temperature | -40 Degrees F |
| Embedded Surge Suppressor | No |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Horsepower @ Single Phase - 240V AC | 3 hp |
| Full Load Current - Resistive | 32 A |
| Conventional Free Air Thermal Current | 10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit) |
Description
The Schneider Electric LC1D18G7 is a TeSys IEC magnetic contactor with a 120V AC coil and screw clamp terminals. This contactor switches power to a load by opening and closing its main contacts when the coil is energized or de-energized. It is rated for 15 hp at 575V three-phase and carries certifications including UL, CSA, IEC, and CCC.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!