- Coil Voltage: 110V AC
- HP @ 3 Phase - 575V: 125 hp
- Rated Breaking Capacity: 1400 A @ 440V
- Fuse Amps: 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
- Overvoltage Category: CAT III
- Signalling Circuit Frequency: 25 to 400 Hz
Specifications
| Part Number | LC1D150F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 120 mm |
| Overall Depth | 136 mm |
| Overall Height | 158 mm |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CCC, GOST, DNV, UL, LROS, BV, GL, RINA, CSA, UKCA, CE, THIEC 60068-2-30 |
| HP @ 3 Phase - 575V | 125 hp |
| Series | LC1D |
| Rated Breaking Capacity | 1400 A @ 440V |
| Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Operating Time | 20 to 35 ms (Closing), 40 to 75 ms (Opening) |
| Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
| Max. Operating Watts | 40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e) |
| Includes Protective Cover | Yes |
| Hold VA | 2 to 18 VA |
| Fuse Amps | 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit) |
| Overvoltage Category | CAT III |
| Fire Rating | UL 94 V1 |
| Operating Speed | 1200 cycles per hr |
| Watts Loss | 3 to 4.5W |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Application | Motor Control, Resistive Load |
| Inrush VA | 280 to 350 VA |
| IP Rating | IP20 |
| Electrical Durability | 0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V) |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Switching Voltage | 17 V (Signalling Circuit) |
| Mechanical Durability | 8 Mcycles |
| Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
| Impedance | 0.6 mOhm |
| Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
| Impulse Withstand Voltage | 8 kV |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit) |
| Non-Overlap Time | 1.5 ms |
| Switching Current | 5 mA (Signalling Circuit) |
| Net Weight | 2.5 kg |
| Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz) |
| Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Control Circuit Type | AC 50/60 Hz standard |
| Control Circuit Voltage | 110 V AC 50/60 Hz |
| Rated Operational Voltage | Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
| Protective Cover | With |
| Maximum Operating Rate | 1200 cyc/h 140°F (60°C) |
| Climatic Withstand | IACS E10 exposure to damp heat |
| Contact Compatibility | M13 |
| Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
| Pole Contact Composition | 3 NO |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Heat Dissipation | 3 to 4.5 W at 50/60 Hz |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms) |
| Pollution Degree | 3 |
| Rated Operational Current | 200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
| Utilisation Category | AC-4; AC-3; AC-1; AC-3e |
| Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
| Conventional Free Air Thermal Current | 200 A (at 140°F (60°C)) for power circuit |
| Inrush Power in VA | 280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C)) |
| Contactor Application | Motor control; Resistive load |
| Safety Reliability Level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Protective Treatment | THIEC 60068-2-30 |
| Power Dissipation Per Pole | 24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e |
| Horsepower @ Three Phase - 208V AC | 40 hp |
| Horsepower @ Three Phase - 480V AC | 100 hp |
| Full Load Current - Inductive | 150 A |
| Full Load Current - Resistive | 200 A |
| Horsepower @ Three Phase - 240V AC | 50 hp |
| Maximum Voltage Rating | 1000V AC, 300V DC |
| Maximum Operating Temperature | 140 Degrees F |
| Mounting Style | Plate, Rail |
| Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Description
The Schneider Electric LC1D150F7 is an IEC magnetic contactor from the LC1D series. This non-reversing, three-pole contactor switches electrical loads and is rated for 150 A with a breaking capacity of 1400 A at 440V. It operates on a 110V AC coil voltage and includes one normally open and one normally closed auxiliary contact with screw clamp terminals. The part complies with standards including UL 508, CSA, IEC 60947-4-1, and EN 60947-4-1.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 110V AC
- HP @ 3 Phase - 575V: 125 hp
- Rated Breaking Capacity: 1400 A @ 440V
- Fuse Amps: 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
- Overvoltage Category: CAT III
- Signalling Circuit Frequency: 25 to 400 Hz
Specifications
| Part Number | LC1D150F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Width | 120 mm |
| Overall Depth | 136 mm |
| Overall Height | 158 mm |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CCC, GOST, DNV, UL, LROS, BV, GL, RINA, CSA, UKCA, CE, THIEC 60068-2-30 |
| HP @ 3 Phase - 575V | 125 hp |
| Series | LC1D |
| Rated Breaking Capacity | 1400 A @ 440V |
| Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Operating Time | 20 to 35 ms (Closing), 40 to 75 ms (Opening) |
| Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
| Max. Operating Watts | 40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e) |
| Includes Protective Cover | Yes |
| Hold VA | 2 to 18 VA |
| Fuse Amps | 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit) |
| Overvoltage Category | CAT III |
| Fire Rating | UL 94 V1 |
| Operating Speed | 1200 cycles per hr |
| Watts Loss | 3 to 4.5W |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Application | Motor Control, Resistive Load |
| Inrush VA | 280 to 350 VA |
| IP Rating | IP20 |
| Electrical Durability | 0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V) |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Switching Voltage | 17 V (Signalling Circuit) |
| Mechanical Durability | 8 Mcycles |
| Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
| Impedance | 0.6 mOhm |
| Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
| Impulse Withstand Voltage | 8 kV |
| Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit) |
| Non-Overlap Time | 1.5 ms |
| Switching Current | 5 mA (Signalling Circuit) |
| Net Weight | 2.5 kg |
| Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz) |
| Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Control Circuit Type | AC 50/60 Hz standard |
| Control Circuit Voltage | 110 V AC 50/60 Hz |
| Rated Operational Voltage | Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
| Protective Cover | With |
| Maximum Operating Rate | 1200 cyc/h 140°F (60°C) |
| Climatic Withstand | IACS E10 exposure to damp heat |
| Contact Compatibility | M13 |
| Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
| Pole Contact Composition | 3 NO |
| Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Heat Dissipation | 3 to 4.5 W at 50/60 Hz |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms) |
| Pollution Degree | 3 |
| Rated Operational Current | 200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
| Utilisation Category | AC-4; AC-3; AC-1; AC-3e |
| Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
| Conventional Free Air Thermal Current | 200 A (at 140°F (60°C)) for power circuit |
| Inrush Power in VA | 280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C)) |
| Contactor Application | Motor control; Resistive load |
| Safety Reliability Level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Protective Treatment | THIEC 60068-2-30 |
| Power Dissipation Per Pole | 24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e |
| Horsepower @ Three Phase - 208V AC | 40 hp |
| Horsepower @ Three Phase - 480V AC | 100 hp |
| Full Load Current - Inductive | 150 A |
| Full Load Current - Resistive | 200 A |
| Horsepower @ Three Phase - 240V AC | 50 hp |
| Maximum Voltage Rating | 1000V AC, 300V DC |
| Maximum Operating Temperature | 140 Degrees F |
| Mounting Style | Plate, Rail |
| Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Description
The Schneider Electric LC1D150F7 is an IEC magnetic contactor from the LC1D series. This non-reversing, three-pole contactor switches electrical loads and is rated for 150 A with a breaking capacity of 1400 A at 440V. It operates on a 110V AC coil voltage and includes one normally open and one normally closed auxiliary contact with screw clamp terminals. The part complies with standards including UL 508, CSA, IEC 60947-4-1, and EN 60947-4-1.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!