Great reasons to buy from us:
-
Quality
Quality Guaranteed -
Free shipping
Fast Shipping -
Fast Shipping
Great Value -
Free shipping
Secure Online Ordering
- Coil Voltage: 110V AC
- HP @ 3 Phase - 575V: 10 hp
- Enclosure NEMA Rating: No Enclosure
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Rated Making Capacity: 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
- Rated Breaking Capacity: 250 A @ 440V
Specifications
| Part Number | LC1D12F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Depth | 3.39 in |
| Overall Height | 3.03 in |
| Overall Width | 1.77 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| Frame / Series / Class / Code | TeSys |
| Series | TeSys Deca |
| Reversing | No |
| HP @ 3 Phase - 575V | 10 hp |
| Enclosure NEMA Rating | No Enclosure |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Max. Operating Watts | 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Switching Current | 5 mA (Signalling Circuit) |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| Non-Overlap Time | 1.5 ms |
| Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
| Rated Insulation Volts | 600/690V |
| Rated Breaking Capacity | 250 A @ 440V |
| Tightening Torque | 1.7 Nm |
| Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
| Features | Without Built-In Suppressor Module |
| Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Operating Speed | 3600 cycles per hr |
| Fuse Amps | 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit) |
| Net Weight | 0.325 kg |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Application | Motor Control, Resistive Load |
| Fire Rating | UL 94 V1 |
| Switching Voltage | 17 V (Signalling Circuit) |
| IP Rating | IP20 |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Mechanical Durability | 15 Mcycles |
| Inrush VA | 70 VA |
| Overvoltage Category | CAT III |
| Electrical Durability | 2 Mcycles (12 A, AC-3, Less than 440 V); 0.8 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (12 A, AC-3e, Less than 440 V) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Watts Loss | 2 to 3W |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Impulse Withstand Voltage | 6 kV |
| Includes Protective Cover | Yes |
| Impedance | 2.5 mOhm |
| Mechanical Operating Durability | 15,000,000 |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Horsepower @ Three Phase - 208V AC | 3 hp |
| Maximum Operating Temperature | 140 Degrees F |
| Maximum Voltage Rating | 690V AC |
| Full Load Current - Inductive | 12:00 AM |
| Includes Auxiliary Contacts | Yes |
| Minimum Operating Temperature | -40 Degrees F |
| Frequency | 50/60 Hz |
| Embedded Surge Suppressor | No |
| Horsepower @ Single Phase - 120V AC | 1/2 hp |
| Full Load Current - Resistive | 25 A |
| Number of Normally Open Main Contacts | 3 |
| NEMA Enclosure Rating | No Enclosure |
| Mounting Style | DIN Rail, Plate |
| Phase | Three |
| Horsepower @ Three Phase - 480V AC | 7 1/2 hp |
| Contactor Style | IEC |
| Horsepower @ Single Phase - 240V AC | 2 hp |
| Horsepower @ Three Phase - 240V AC | 3 hp |
| Electrical Operating Durability | 2,000,000, 800,000 |
| Horsepower @ Three Phase - 600V AC | 10 hp |
| Conventional Free Air Thermal Current | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Description
The Schneider Electric LC1D12F7 is a TeSys Deca IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It operates with a 110V AC coil voltage and features screw clamp terminals. This unit is rated for 10 hp at 575V three-phase and carries certifications including UL, CSA, IEC, and CCC.
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
Description
- Coil Voltage: 110V AC
- HP @ 3 Phase - 575V: 10 hp
- Enclosure NEMA Rating: No Enclosure
- Control Circuit Voltage Limits: Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Rated Making Capacity: 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
- Rated Breaking Capacity: 250 A @ 440V
Specifications
| Part Number | LC1D12F7 |
| Brand | Schneider Electric |
| Auxiliary Contact Form | 1NC/1NO |
| Coil Voltage | 110V AC |
| Number of Poles | 3 |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw Clamp |
| Working Height | Up to 9842.52 ft |
| Overall Depth | 3.39 in |
| Overall Height | 3.03 in |
| Overall Width | 1.77 in |
| Item | IEC Magnetic Contactor |
| Number of Auxillary Contacts | 2 |
| Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
| Frame / Series / Class / Code | TeSys |
| Series | TeSys Deca |
| Reversing | No |
| HP @ 3 Phase - 575V | 10 hp |
| Enclosure NEMA Rating | No Enclosure |
| Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
| Max. Operating Watts | 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
| Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
| Switching Current | 5 mA (Signalling Circuit) |
| Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
| Non-Overlap Time | 1.5 ms |
| Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
| Rated Insulation Volts | 600/690V |
| Rated Breaking Capacity | 250 A @ 440V |
| Tightening Torque | 1.7 Nm |
| Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
| Features | Without Built-In Suppressor Module |
| Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
| Operating Speed | 3600 cycles per hr |
| Fuse Amps | 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit) |
| Net Weight | 0.325 kg |
| Signalling Circuit Frequency | 25 to 400 Hz |
| Application | Motor Control, Resistive Load |
| Fire Rating | UL 94 V1 |
| Switching Voltage | 17 V (Signalling Circuit) |
| IP Rating | IP20 |
| Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
| Mechanical Durability | 15 Mcycles |
| Inrush VA | 70 VA |
| Overvoltage Category | CAT III |
| Electrical Durability | 2 Mcycles (12 A, AC-3, Less than 440 V); 0.8 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (12 A, AC-3e, Less than 440 V) |
| Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
| Watts Loss | 2 to 3W |
| Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
| Impulse Withstand Voltage | 6 kV |
| Includes Protective Cover | Yes |
| Impedance | 2.5 mOhm |
| Mechanical Operating Durability | 15,000,000 |
| Resistance Properties | Fire Resistant, Insulation Resistant |
| Horsepower @ Three Phase - 208V AC | 3 hp |
| Maximum Operating Temperature | 140 Degrees F |
| Maximum Voltage Rating | 690V AC |
| Full Load Current - Inductive | 12:00 AM |
| Includes Auxiliary Contacts | Yes |
| Minimum Operating Temperature | -40 Degrees F |
| Frequency | 50/60 Hz |
| Embedded Surge Suppressor | No |
| Horsepower @ Single Phase - 120V AC | 1/2 hp |
| Full Load Current - Resistive | 25 A |
| Number of Normally Open Main Contacts | 3 |
| NEMA Enclosure Rating | No Enclosure |
| Mounting Style | DIN Rail, Plate |
| Phase | Three |
| Horsepower @ Three Phase - 480V AC | 7 1/2 hp |
| Contactor Style | IEC |
| Horsepower @ Single Phase - 240V AC | 2 hp |
| Horsepower @ Three Phase - 240V AC | 3 hp |
| Electrical Operating Durability | 2,000,000, 800,000 |
| Horsepower @ Three Phase - 600V AC | 10 hp |
| Conventional Free Air Thermal Current | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Description
The Schneider Electric LC1D12F7 is a TeSys Deca IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It operates with a 110V AC coil voltage and features screw clamp terminals. This unit is rated for 10 hp at 575V three-phase and carries certifications including UL, CSA, IEC, and CCC.
Shipping
Shipping and dispatch
Shipping method and available services depend on the item and delivery address. Check the product shipping information and checkout for shipping options and charges.
Dispatch times vary by product and supplier. Any supplier dispatch estimate shown is subject to availability. Transit time begins after shipment and is additional to dispatch time.
Freight shipments
Products identified as freight ship by truck. Review the available delivery service and charges at checkout; delivery arrangements depend on the selected service.
Inspection and Damage:
Upon delivery, please inspect the carton and contents for any damage. If you find any damage, document it on the driver's delivery receipt and contact us immediately at support@proreplacementparts.com no later than 24 hours from the delivery time. We cannot accept responsibility for damage that is not noted on the driver's delivery receipt at the time of delivery.
Order Cancellations:
All order cancellations must be requested within 24 hours of placing the order. After this period, our standard return policy will take effect.
Thank you for choosing Pro Replacement Parts. We are dedicated to providing you with the best service and ensuring your orders are delivered in a timely and efficient manner. If you have any questions or need further assistance, please don't hesitate to contact us.
Why Buy From Us?
Exact part numbers. Every listing starts with the manufacturer part number, so you can match it to the part in your equipment before you order. Not sure it fits? Ask us first.
Clear shipping. Check the product shipping information for the shipping method and any supplier dispatch estimate. Shipping options and charges are shown at checkout.
Real people. Call 617-286-6694 (Monday to Friday, 9 AM to 6 PM ET) or email support@proreplacementparts.com with a part number or model number.
Returns. Unopened parts can be returned within 30 days. Electrical and gas parts are final sale once opened. Details are on our Returns & Refunds page.
Warranty/Returns
Your purchase is covered by the Manufacturer’s Limited Warranty.
For return/refund information, please visit our Returns & Refunds page.
No reviews yet. Be the first to review this product!