{"product_id":"p499acp-105k","title":"P499ACP-105K Johnson Controls Pressure Transmitter, 0–500 psi, 4–20 mA DC","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp.:\u003c\/strong\u003e -40 Degrees to 185 Degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -40 Degrees F to 257 Degrees F (-40 Degrees C to 125 Degrees C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Connection Size:\u003c\/strong\u003e 1\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Connection Size - Transmitter:\u003c\/strong\u003e 1\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurst Pressure:\u003c\/strong\u003e 5x Range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP499ACP-105K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eJohnson Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003e6 1\/2 Ft (2 m) Wire Harness, Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eP499\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4 to 20mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd\u003e-40 Degrees to 185 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 Degrees F to 257 Degrees F (-40 Degrees C to 125 Degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e0.875 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection Size\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection Size - Transmitter\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturers Warranty Length\u003c\/td\u003e\n\u003ctd\u003e3 yr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Length\u003c\/td\u003e\n\u003ctd\u003e78.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.5 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Length\u003c\/td\u003e\n\u003ctd\u003e3.19 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003ePressure Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor Use With Media Type\u003c\/td\u003e\n\u003ctd\u003eAmmonia, Carbon Dioxide, Condensate, Fluids, Gas, Glycol, Refrigerants, Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurst Pressure\u003c\/td\u003e\n\u003ctd\u003e5x Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e1\/4 in Male SAE 45 Degrees Flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pressure\u003c\/td\u003e\n\u003ctd\u003e0 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e3-Pin Packard Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitting Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsically Safe\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput - Transmitter\u003c\/td\u003e\n\u003ctd\u003e4 to 20mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e100 Mega Ohm @ 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp. - Transmitter\u003c\/td\u003e\n\u003ctd\u003e-40 Degrees to 185 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure (PSI)\u003c\/td\u003e\n\u003ctd\u003e1,000 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection Type\u003c\/td\u003e\n\u003ctd\u003eSAE 45 Degrees Flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003ePressure Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eClass I Div. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Entry - Transmitter\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection Gender\u003c\/td\u003e\n\u003ctd\u003eMale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Wires\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e185 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Units\u003c\/td\u003e\n\u003ctd\u003epsig\/bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection Type - Transmitter\u003c\/td\u003e\n\u003ctd\u003eSAE Flare Internal Thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion\/Fire Proof\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003e1% Total Error Band, Environmentally Protected Electronics, Long Operating Life, Single-Piece Machined Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Required\u003c\/td\u003e\n\u003ctd\u003e9 to 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor Use With\u003c\/td\u003e\n\u003ctd\u003eAny Corrosive or Non-Corrosive Pressure Medium That is Compatible with 17-4PH Stainless Steel, Including Water, Condensate, Carbon Dioxide, Glycol, Most Refrigerants Including Ammonia, and Many Other Compatible Fluids and Gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEMA Rating\u003c\/td\u003e\n\u003ctd\u003e7 - Class 1, Division 2, Groups A, B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Materials\u003c\/td\u003e\n\u003ctd\u003e17-4PH Stainless Steel Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 500 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance\u003c\/td\u003e\n\u003ctd\u003eMinimum Between Transducer Body and Any Wire: 100 megaohm @ 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating - Transmitter\u003c\/td\u003e\n\u003ctd\u003eClass I, Div. 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections - Transmitter\u003c\/td\u003e\n\u003ctd\u003ePackard Connector with 6-1\/2 ft Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Materials - Transmitters\u003c\/td\u003e\n\u003ctd\u003e17-4PH Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Units - Transmitter\u003c\/td\u003e\n\u003ctd\u003epsig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e3-Pin Packard Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure\u003c\/td\u003e\n\u003ctd\u003e2x Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Values - Transmitter\u003c\/td\u003e\n\u003ctd\u003e0 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - Transmitter\u003c\/td\u003e\n\u003ctd\u003e+\/-1.00% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible With\u003c\/td\u003e\n\u003ctd\u003eAll Media Compatible with 17-4PH Stainless Steel, Including Ammonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Required - Transmitters\u003c\/td\u003e\n\u003ctd\u003e12 to 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003e17-4PH Stainless Steel Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e9 to 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Media Temperature - Maximum\u003c\/td\u003e\n\u003ctd\u003e185 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Type Measured\u003c\/td\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance - Maximum\u003c\/td\u003e\n\u003ctd\u003e100 Mega Ohm @ 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Measurement - Minimum\u003c\/td\u003e\n\u003ctd\u003e0 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNot Specified Intrinsically Safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes NIST-Traceable Calibration Certificate\u003c\/td\u003e\n\u003ctd\u003eNo NIST-Traceable Calibration Certificate Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Media Temperature - Minimum\u003c\/td\u003e\n\u003ctd\u003e-40 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e4 to 20mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Measurement - Maximum\u003c\/td\u003e\n\u003ctd\u003e500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Johnson Controls P499ACP-105K is a pressure transmitter from the P499 series. This type of sensor converts pressure into a 4-20 mA output signal, with a 500 psi range. It includes a 6 1\/2 ft (2 m) wire harness and transducer, and is compatible with media such as ammonia, carbon dioxide, condensate, fluids, gas, glycol, refrigerants, and water.\u003c\/p\u003e","brand":"Johnson Controls","offers":[{"title":"Default Title","offer_id":54087697989845,"sku":"P499ACP-105K","price":220.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/P499ACP105K.jpg?v=1781995439","url":"https:\/\/proreplacementparts.com\/products\/p499acp-105k","provider":"Pro Replacement Parts","version":"1.0","type":"link"}