{"product_id":"lub12","title":"LUB12 Square D Motor Starter Non-Reversing","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Operation:\u003c\/strong\u003e -13 to 140°F (-25 to 60°C) with LUCM; -13 to 158°F (-25 to 70°C) with LUCA, LUCB, LUCC, LUCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity To Voltage Dips:\u003c\/strong\u003e 70% \/ 500 ms IEC 61000-4-11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Impulse Withstand Voltage:\u003c\/strong\u003e 6 kVIEC 60947-6-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Circuit Voltage:\u003c\/strong\u003e 24 V AC 50\/60 Hz; 24 V DC; 48 to 72 V AC 50\/60 Hz; 48 to 72 V DC; 110 to 240 V AC 50\/60 Hz; 110 to 220 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 690 V AC power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Service Breaking Capacity:\u003c\/strong\u003e 50 kA 230 V; 50 kA 440 V; 10 kA 500 V; 4 kA 690 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLUB12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.77 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e6.06 in (154 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e4.96 in (126 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6561.68 ft (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability For Isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles Description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Operation\u003c\/td\u003e\n\u003ctd\u003e-13 to 140°F (-25 to 60°C) with LUCM; -13 to 158°F (-25 to 70°C) with LUCA, LUCB, LUCC, LUCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Resistance\u003c\/td\u003e\n\u003ctd\u003e1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility Code\u003c\/td\u003e\n\u003ctd\u003eLUB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit; 50 ms Greater than or Equal to 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit; 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit; 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit; 75 ms closing with LUCM control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity To Radioelectric Fields\u003c\/td\u003e\n\u003ctd\u003e10 V IEC 61000-4-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Reliability Level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity To Voltage Dips\u003c\/td\u003e\n\u003ctd\u003e70% \/ 500 ms IEC 61000-4-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance To Fast Transients\u003c\/td\u003e\n\u003ctd\u003e2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree Of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 IEC 60947-1 front panel and wired terminals); IP20 IEC 60947-1 other faces); IP40 IEC 60947-1 front panel outside connection zone)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kVIEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50\/60 Hz; 24 V DC; 48 to 72 V AC 50\/60 Hz; 48 to 72 V DC; 110 to 240 V AC 50\/60 Hz; 110 to 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e2 gn 5 to 300 Hz) power poles open IEC 60068-2-27; 4 gn 5 to 300 Hz) power poles closed IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) flat 0.20 in (5 mm); Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) Philips no 1 0.20 in (5 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) flat 0.24 in (6 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) Philips No 2 0.24 in (6 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) pozidriv No 2 0.24 in (6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing Mode\u003c\/td\u003e\n\u003ctd\u003eClipped DIN rail; Screw-fixed plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Dissipating Shock Wave\u003c\/td\u003e\n\u003ctd\u003e1 kV serial mode 24 to 240 V AC IEC 60947-6-2; 1 kV serial mode 48 to 220 V DC IEC 60947-6-2; 2 kV common mode 24 to 240 V AC IEC 60947-6-2; 2 kV common mode 48 to 220 V DC IEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Separation Of Circuit\u003c\/td\u003e\n\u003ctd\u003e400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Or Component Type\u003c\/td\u003e\n\u003ctd\u003eNon reversing power base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contacts Type\u003c\/td\u003e\n\u003ctd\u003eLinked contacts 1 NO + 1 NC) IEC 60947-4-1; Mirror contact 1 NC) IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance To Radiated Fields\u003c\/td\u003e\n\u003ctd\u003e9.14 V\/m (10 V\/m) 3 IEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eMotor control; Motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTH IEC 60068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance To Electrostatic Discharge\u003c\/td\u003e\n\u003ctd\u003e8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation Category\u003c\/td\u003e\n\u003ctd\u003eAC-43; AC-44; AC-41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air Thermal Current\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e50 kA 230 V; 50 kA 440 V; 10 kA 500 V; 4 kA 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - Terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²) flexible with cable end; Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.75 to 1.5 mm²) flexible without cable end; Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.75 to 1.5 mm²) rigid; Control circuit screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²) flexible with cable end; Control circuit screw clamp terminals 2 0.00 to 0.00 in² (0.75 to 1.5 mm²) flexible without cable end; Control circuit screw clamp terminals 2 0.00 to 0.00 in² (0.75 to 1.5 mm²) rigid; Power circuit screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) rigid; Power circuit screw clamp terminals 1 0.00 to 0.01 in² (1 to 6 mm²) flexible with cable end; Power circuit screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) flexible without cable end; Power circuit screw clamp terminals 2 0.00 to 0.01 in² (1 to 6 mm²) flexible with cable end; Power circuit screw clamp terminals 2 0.00 to 0.01 in² (1 to 6 mm²) rigid; Power circuit screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) flexible without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC 60947-6-2 3; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to 185°F (-40 to 85°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Consumption\u003c\/td\u003e\n\u003ctd\u003e130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 150 mA 24 V DC I maximum while closing with LUCM; 280 mA 110 to 220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 280 mA 110 to 240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 280 mA 48 to 72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 280 mA 48 to 72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD; 35 mA 110 to 220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD; 35 mA 110 to 240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD; 35 mA 48 to 72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD; 35 mA 48 to 72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD; 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD; 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD; 70 mA 24 V DC I rms sealed with LUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e40 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity To Microbreaks\u003c\/td\u003e\n\u003ctd\u003e3 ms control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e2 W control circuit with LUCA, LUCB, LUCC, LUCD; 1.7 W control circuit with LUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e15 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd\u003e12 A Less than or Equal to 440 V; 12 A 500 V; 9 A 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D LUB12 is a non-reversing motor starter. This type of device controls the power supply to an electric motor, enabling it to start and stop. It operates with control circuit voltages of 24 V AC\/DC, 48 to 72 V AC\/DC, or 110 to 240 V AC\/DC and meets EN, IEC, UL, and CSA standards.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":54074870268117,"sku":"LUB12","price":352.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/LUB12.jpg?v=1781978504","url":"https:\/\/proreplacementparts.com\/products\/lub12","provider":"Pro Replacement Parts","version":"1.0","type":"link"}