{"product_id":"lrd12","title":"LRD12 Schneider Electric Overload Relay, 1NC\/1NO, 690V AC, adjustable 5.5 A to 8 A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Operation:\u003c\/strong\u003e -20-60°C without derating IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Frequency:\u003c\/strong\u003e 0 to 400 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Storage:\u003c\/strong\u003e -60-70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Failure Sensitivity:\u003c\/strong\u003e tripping current 130 % of Ir on two phase, the last one at 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Operating Temperature:\u003c\/strong\u003e -4 Degrees F\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLRD12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Form\u003c\/td\u003e\n\u003ctd\u003e1NC\/1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Overload Relay Current Setting\u003c\/td\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overload Relay Current Setting\u003c\/td\u003e\n\u003ctd\u003e8:00 AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection Type\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.62\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height - Relay\u003c\/td\u003e\n\u003ctd\u003e3.62 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height - Relay\u003c\/td\u003e\n\u003ctd\u003e3.62 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height\u003c\/td\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height\u003c\/td\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, GB\/T 14048.4, GB\/T 14048.5, REACH, RoHS, UL 60947-4-1, UL 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eSingle Phase Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse With - Contactors and Starters\u003c\/td\u003e\n\u003ctd\u003eMfr. Series LC1D09 to LC1D32 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor Use With\u003c\/td\u003e\n\u003ctd\u003eLC1D09 thru LC1D32 Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class - Overload\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Method\u003c\/td\u003e\n\u003ctd\u003eBimetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter Type\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Operation\u003c\/td\u003e\n\u003ctd\u003e-20-60°C without derating IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Protection Adjustment Range\u003c\/td\u003e\n\u003ctd\u003e5.5-8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic Withstand\u003c\/td\u003e\n\u003ctd\u003eIACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Application\u003c\/td\u003e\n\u003ctd\u003emotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Overload Class\u003c\/td\u003e\n\u003ctd\u003eclass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003econtrol circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e4 A gG signalling circuit || 4 A BS signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Threshold\u003c\/td\u003e\n\u003ctd\u003e1.14 +\/- 0.06 Ir IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eRed push-button stop || Blue push-button reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eIEC || UL || CSA || CCC || EAC || BV || RINA || DNV-GL || LROS (Lloyds register of shipping) || ATEX INERIS || UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eTeSys LRD || TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eLRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Robustness\u003c\/td\u003e\n\u003ctd\u003evibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Retardance\u003c\/td\u003e\n\u003ctd\u003eV1 conforming to UL 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Storage\u003c\/td\u003e\n\u003ctd\u003e-60-70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Failure Sensitivity\u003c\/td\u003e\n\u003ctd\u003etripping current 130 % of Ir on two phase, the last one at 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Current\u003c\/td\u003e\n\u003ctd\u003e1.5 A 240 V AC-15 signalling circuit || 0.1 A 250 V DC-13 signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - Terminals\u003c\/td\u003e\n\u003ctd\u003econtrol circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd\u003eLC1D18 || LC1D25 || LC1D32 || LC1D12 || LC1D09 || LC1D38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1.89 kV 50 Hz IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eDC || AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys || TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Or Component Type\u003c\/td\u003e\n\u003ctd\u003edifferential thermal overload relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e140 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDirect To Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Type\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Style\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible with Series\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 600 V CSA; Power circuit 600 V UL; Power circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 0 to 400 Hz power circuit IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air Thermal Current\u003c\/td\u003e\n\u003ctd\u003e5 A signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Clss\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric LRD12 is a thermal overload relay with single phase sensitivity, rated for a maximum voltage of 690V AC and a current range of 5.5 to 8 A. It protects motors by monitoring current and tripping the circuit in the event of an overload. This relay is designed for use with LC1D09 through LC1D32 contactors and complies with standards including IEC 60947-4-1 and UL 60947-4-1.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074917912789,"sku":"LRD12","price":81.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/LRD12.jpg?v=1781979317","url":"https:\/\/proreplacementparts.com\/products\/lrd12","provider":"Pro Replacement Parts","version":"1.0","type":"link"}