{"product_id":"lr9d32","title":"LR9D32 Schneider Electric Overload Relay, 1NO\/1NC auxiliary contacts, 690V AC","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Storage:\u003c\/strong\u003e -55-80°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Failure Sensitivity:\u003c\/strong\u003e phase difference \u0026gt; 40% 3-3 s IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Operation:\u003c\/strong\u003e -25-70°C IEC 60255-8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage:\u003c\/strong\u003e power circuit 1000 V || signalling circuit 690 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 690 V power circuit || 660 V signalling circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLR9D32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Form\u003c\/td\u003e\n\u003ctd\u003e1NC\/1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Overload Relay Current Setting\u003c\/td\u003e\n\u003ctd\u003e6.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overload Relay Current Setting\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class\u003c\/td\u003e\n\u003ctd\u003e5\/10\/20\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection Type\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e79.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height - Relay\u003c\/td\u003e\n\u003ctd\u003e2.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e72.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height\u003c\/td\u003e\n\u003ctd\u003e2.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCCC, CSA, CSA C22.2, GB\/T 14048.4, IEC 60947-4-1, Product CULus, TÜV, UL 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate Mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class - Overload\u003c\/td\u003e\n\u003ctd\u003e10, 20, 30, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ Series \/ Class \/ Code\u003c\/td\u003e\n\u003ctd\u003eSeries LRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Method\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eChina RoHS Regulation, Circularity Profile, Environmental Disclosure, EU RoHS Directive, Green Premium Product, Mercury Free, REACh free of SVHC, REACh Regulation, RoHS Exemption Information, Toxic Heavy Metal Free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse With - Contactors and Starters\u003c\/td\u003e\n\u003ctd\u003eMfr. Series LC1D09 to LC1D32 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Storage\u003c\/td\u003e\n\u003ctd\u003e-55-80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd\u003eLC1D09 || LC1D25 || LC1D32 || LC1D38 || LC1D12 || LC1D18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003econtrol circuit 0.8 N.m screw clamp terminals || power circuit 3.1 N.m screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - Terminals\u003c\/td\u003e\n\u003ctd\u003econtrol circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable end || power circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eIECEE CB Scheme || UL || CSA || CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e5 A gG signalling circuit || 5 A BS signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Failure Sensitivity\u003c\/td\u003e\n\u003ctd\u003ephase difference \u0026gt; 40% 3-3 s IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Protection Adjustment Range\u003c\/td\u003e\n\u003ctd\u003e6.4-32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Application\u003c\/td\u003e\n\u003ctd\u003emotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption In W\u003c\/td\u003e\n\u003ctd\u003e300 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eRed push-button stop and manual reset || White 2 microswitches adjustable trip class || Red knob automatic reset || Gray dial full-load current adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Range\u003c\/td\u003e\n\u003ctd\u003e1.5 to 4 min - automatic reset time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Operation\u003c\/td\u003e\n\u003ctd\u003e-25-70°C IEC 60255-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Robustness\u003c\/td\u003e\n\u003ctd\u003evibrations 10 to 150 Hz6 Gn IEC 60068-2-6 || shocks 11 ms15 gn IEC 60068-2-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd\u003esurge withstand 2 kV common mode IEC 61000-4-5 || resistance to electrostatic discharge 8 kV IEC 61000-4-2 || immunity to radiated radio-electrical interference 10 V\/m IEC 61000-4-3 || immunity to fast transients 2 kV IEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Or Component Type\u003c\/td\u003e\n\u003ctd\u003eelectronic thermal overload relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6561.68 ft (2000 m) without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e6 kV 50 Hz IEC 60255-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Overload Class\u003c\/td\u003e\n\u003ctd\u003eclass 5-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Threshold\u003c\/td\u003e\n\u003ctd\u003e1.25 In IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eLR9D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eTeSys LRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Type\u003c\/td\u003e\n\u003ctd\u003eAuto, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDirect To Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible with Series\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca, TeSys LRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Style\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003epower circuit 1000 V || signalling circuit 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air Thermal Current\u003c\/td\u003e\n\u003ctd\u003e5 A signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V power circuit || 660 V signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Clss\u003c\/td\u003e\n\u003ctd\u003e5\/10\/20\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric LR9D32 is a Series LRD thermal overload relay. It protects motors from overload by monitoring current and opening the control circuit when the current exceeds the set range of 6.4 to 32 A. This relay has a maximum voltage rating of 690V AC and complies with standards including IEC 60947-4-1, UL 60947-4-1, and CSA C22.2.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074931118293,"sku":"LR9D32","price":129.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/LR9D32.jpg?v=1781979600","url":"https:\/\/proreplacementparts.com\/products\/lr9d32","provider":"Pro Replacement Parts","version":"1.0","type":"link"}