{"product_id":"lr3d32l","title":"LR3D32L Schneider Electric Overload Relay, 1NO\/1NC, 23 A minimum\/32 A maximum, 690V AC","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Frequency:\u003c\/strong\u003e 0 to 400 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Operation:\u003c\/strong\u003e -20-60°C without derating IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Storage:\u003c\/strong\u003e -60-70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Failure Sensitivity:\u003c\/strong\u003e tripping current 130 % of Ir on two phase, the last one at 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Operating Temperature:\u003c\/strong\u003e -4 Degrees F\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLR3D32L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Form\u003c\/td\u003e\n\u003ctd\u003e1NC\/1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Overload Relay Current Setting\u003c\/td\u003e\n\u003ctd\u003e23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overload Relay Current Setting\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection Type\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height - Relay\u003c\/td\u003e\n\u003ctd\u003e2.99 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height - Relay\u003c\/td\u003e\n\u003ctd\u003e2.99 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height\u003c\/td\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height\u003c\/td\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, REACH, RoHS, UL 60947-4-1, UL 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eNon Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFor Use With\u003c\/td\u003e\n\u003ctd\u003eTeSys D 9-32A, TeSys N Size 00-1 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate Mounting\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse With - Contactors and Starters\u003c\/td\u003e\n\u003ctd\u003eMfr. Series LC1D09 to LC1D32 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Class - Overload\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Method\u003c\/td\u003e\n\u003ctd\u003eBimetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter Type\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic Withstand\u003c\/td\u003e\n\u003ctd\u003eIACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eDC || AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eRed push-button stop || Blue push-button reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Robustness\u003c\/td\u003e\n\u003ctd\u003eshocks15 Gn for 11 ms IEC 60068-2-7 || vibrations3 GN IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Operation\u003c\/td\u003e\n\u003ctd\u003e-20-60°C without derating IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Protection Adjustment Range\u003c\/td\u003e\n\u003ctd\u003e23-32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eTeSys LRD || TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003econtrol circuit 1.7 N.m screw clamp terminals || power circuit 2.5 N.m screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Or Component Type\u003c\/td\u003e\n\u003ctd\u003enon differential thermal overload relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eIEC || UL || CSA || EAC || ABS || ATEX INERIS || UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Application\u003c\/td\u003e\n\u003ctd\u003emotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - Terminals\u003c\/td\u003e\n\u003ctd\u003econtrol circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 1.5-10 mm² solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e4 A gG signalling circuit || 4 A BS signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Threshold\u003c\/td\u003e\n\u003ctd\u003e1.14 +\/- 0.06 Ir IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Overload Class\u003c\/td\u003e\n\u003ctd\u003eclass 20 IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Storage\u003c\/td\u003e\n\u003ctd\u003e-60-70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eLR3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1.89 kV 50 Hz IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Failure Sensitivity\u003c\/td\u003e\n\u003ctd\u003etripping current 130 % of Ir on two phase, the last one at 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd\u003eLC1D38 || LC1D25 || LC1D32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Current\u003c\/td\u003e\n\u003ctd\u003e3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Style\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDirect To Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e140 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Type\u003c\/td\u003e\n\u003ctd\u003eAuto, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible with Series\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air Thermal Current\u003c\/td\u003e\n\u003ctd\u003e5 A signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003epower circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 0 to 400 Hz power circuit IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Clss\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric LR3D32L is a thermal overload relay designed for use with TeSys D 9-32A and TeSys N Size 00-1 contactors. This non-differential overload relay provides motor protection against overload conditions, with a current range of 23 A minimum to 32 A maximum and a maximum voltage rating of 690V AC. It complies with standards including CSA C22.2 No 60947-4-1, EN\/IEC 60947-4-1, and UL 60947-4-1.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074930594005,"sku":"LR3D32L","price":103.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/LR3D32L.jpg?v=1781979591","url":"https:\/\/proreplacementparts.com\/products\/lr3d32l","provider":"Pro Replacement Parts","version":"1.0","type":"link"}