{"product_id":"lc1d40af7","title":"LC1D40AF7 Schneider Electric IEC Magnetic Contactor, 3 Pole, 1NO\/1NC, 110V AC","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Voltage:\u003c\/strong\u003e 110V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHP @ 3 Phase - 575V:\u003c\/strong\u003e 30 hp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Category:\u003c\/strong\u003e CAT III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Amps:\u003c\/strong\u003e 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Circuit Voltage Limits:\u003c\/strong\u003e Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50\/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Breaking Capacity:\u003c\/strong\u003e 800 A @ 440V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLC1D40AF7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Form\u003c\/td\u003e\n\u003ctd\u003e1NC\/1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReversing Capability\u003c\/td\u003e\n\u003ctd\u003eNon-Reversing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Height\u003c\/td\u003e\n\u003ctd\u003eUp to 9842.52 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e2.17 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height\u003c\/td\u003e\n\u003ctd\u003e4.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Depth\u003c\/td\u003e\n\u003ctd\u003e4.72 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003eIEC Magnetic Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Auxillary Contacts\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40:Annex JJ, UL 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eEverlink Power Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHP @ 3 Phase - 575V\u003c\/td\u003e\n\u003ctd\u003e30 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eWithout Built-In Suppressor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes Protective Cover\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Amps\u003c\/td\u003e\n\u003ctd\u003e10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Voltage Limits\u003c\/td\u003e\n\u003ctd\u003eDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50\/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Current\u003c\/td\u003e\n\u003ctd\u003e5 mA (Signalling Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e1.4 Mcycles (60 A, AC-1, Less than 440 V); 1.5 Mcycles (40 A, AC-3, Less than 440 V); 1.5 Mcycles (40 A, AC-3e, Less than 440 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Speed\u003c\/td\u003e\n\u003ctd\u003e3600 cycles per hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Range\u003c\/td\u003e\n\u003ctd\u003eGreater Than 10 MOhms (Signalling Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush VA\u003c\/td\u003e\n\u003ctd\u003e140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e800 A @ 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e17 V (Signalling Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e1.5 mOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operating Watts\u003c\/td\u003e\n\u003ctd\u003e18.5 kW (at 380 to 400V AC 50\/60 Hz AC-3), 11 kW (at 220 to 230V AC 50\/60 Hz AC-3), 22 kW (at 415 to 440V AC 50\/60 Hz AC-3), 22 kW (at 500V AC 50\/60 Hz AC-3), 30 kW (at 660 to 690V AC 50\/60 Hz AC-3), 9 kW (at 400V AC 50\/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50\/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50\/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50\/60 Hz AC-3e), 22 kW (at 500V AC 50\/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50\/60 Hz AC-3e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current\u003c\/td\u003e\n\u003ctd\u003e320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e4 G (Contactor Closed), 2 G (Contactor Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Making Capacity\u003c\/td\u003e\n\u003ctd\u003e140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Attributes\u003c\/td\u003e\n\u003ctd\u003eMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatts Loss\u003c\/td\u003e\n\u003ctd\u003e4 to 5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling Circuit Frequency\u003c\/td\u003e\n\u003ctd\u003e25 to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Volts\u003c\/td\u003e\n\u003ctd\u003e600\/690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Overlap Time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Rating\u003c\/td\u003e\n\u003ctd\u003eUL 94 V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMotor Control, Resistive Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e4 to 19 ms (Opening), 12 to 26 ms (Closing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e6 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold VA\u003c\/td\u003e\n\u003ctd\u003e13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole Contact Composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contacts Type\u003c\/td\u003e\n\u003ctd\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Compatibility\u003c\/td\u003e\n\u003ctd\u003eM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd\u003e60 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h 140°F (60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 9842.52 ft (0 to 3000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e4 to 5 W at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Robustness\u003c\/td\u003e\n\u003ctd\u003eVibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Application\u003c\/td\u003e\n\u003ctd\u003eResistive load; Motor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation Category\u003c\/td\u003e\n\u003ctd\u003eAC-4; AC-1; AC-3; AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTHIEC 60068-2-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Resistance\u003c\/td\u003e\n\u003ctd\u003e1562°F (850°C) IEC 60695-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Power in VA\u003c\/td\u003e\n\u003ctd\u003e140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Reliability Level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e110 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air Thermal Current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140°F (60°C)) for signalling circuit; 60 A (at 140°F (60°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation Per Pole\u003c\/td\u003e\n\u003ctd\u003e2.4 W AC-3; 5.4 W AC-1; 2.4 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic Withstand\u003c\/td\u003e\n\u003ctd\u003eIACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower @ Three Phase - 480V AC\u003c\/td\u003e\n\u003ctd\u003e30 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower @ Three Phase - 240V AC\u003c\/td\u003e\n\u003ctd\u003e10 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load Current - Inductive\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load Current - Resistive\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower @ Three Phase - 208V AC\u003c\/td\u003e\n\u003ctd\u003e10 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower @ Single Phase - 240V AC\u003c\/td\u003e\n\u003ctd\u003e5 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower @ Three Phase - 600V AC\u003c\/td\u003e\n\u003ctd\u003e30 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e140 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Operating Durability\u003c\/td\u003e\n\u003ctd\u003e1,500,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes Auxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Normally Open Main Contacts\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e12 to 26 msec (Closing), 4 to 19 msec (Opening)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Style\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Operating Durability\u003c\/td\u003e\n\u003ctd\u003e6,000,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Properties\u003c\/td\u003e\n\u003ctd\u003eFire Resistant, Insulation Resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature For Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric LC1D40AF7 is a TeSys series IEC magnetic contactor. This contactor uses an electromagnetic coil to open and close power circuits in motor control applications. It features a 110V AC coil, screw clamp terminals, and Everlink power connections, and is rated for 40 amps and 30 hp at 575V three-phase. It complies with standards including IEC 60947-4-1 and UL 60947-4-1.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54073685803221,"sku":"LC1D40AF7","price":295.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/LC1D40AF7.jpg?v=1781965121","url":"https:\/\/proreplacementparts.com\/products\/lc1d40af7","provider":"Pro Replacement Parts","version":"1.0","type":"link"}