{"product_id":"1950-1-2f","title":"1950-1-2F Dwyer Instruments Differential Pressure Sensor for Hazardous Locations","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Line Connection Size:\u003c\/strong\u003e 1\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Hole Diameter:\u003c\/strong\u003e 1\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Limits:\u003c\/strong\u003e Continuous: 1950's - 45\" w.c. (0.11 bar); 1950P's - 35 psi (2.41 bar); 1950P-50 only - 70 psi (4.83 bar). Surge: 1950's - 10 psi (0.69 bar); 1950P's - 50 psi (3.45 bar); 1950P-50 only - 90 psi (6.21 bar).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Limits:\u003c\/strong\u003e -40 to 140Â°F (-40 to 60Â°C); 0 to 140Â°F (-17.8 to 60Â°C)for 1950P-8, 15, 25, and 50. -30 to 130Â°F (-34.4 to 54.4Â°C) for 1950-02.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Differential Pressure Setting:\u003c\/strong\u003e 0.4 in wc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1950-1-2F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDwyer Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCE Listed, CSA, FM, RoHS, UL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Form\u003c\/td\u003e\n\u003ctd\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eExplosion-proof and weatherproof housing provides device protection for outdoor use or harsh environment operation; External set point screw provides easy access that simplifies making adjustments without opening or disassembling enclosure; Easily accessible electrical connection simplifies the installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e3 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Depth\u003c\/td\u003e\n\u003ctd\u003e5 7\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height\u003c\/td\u003e\n\u003ctd\u003e5 7\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Line Connection Size\u003c\/td\u003e\n\u003ctd\u003e1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003eDifferential Pressure Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eDrain Plug, O-Ring Seal in Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e3 screw type, common, normally open and normally closed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDifferential Pressure Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Point Adjustment\u003c\/td\u003e\n\u003ctd\u003eScrew type on top of housing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Limits\u003c\/td\u003e\n\u003ctd\u003eContinuous: 1950's - 45\" w.c. (0.11 bar); 1950P's - 35 psi (2.41 bar); 1950P-50 only - 70 psi (4.83 bar). Surge: 1950's - 10 psi (0.69 bar); 1950P's - 50 psi (3.45 bar); 1950P-50 only - 90 psi (6.21 bar).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, FM, UL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole double-throw (SPDT).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Limits\u003c\/td\u003e\n\u003ctd\u003e-40 to 140Â°F (-40 to 60Â°C); 0 to 140Â°F (-17.8 to 60Â°C)for 1950P-8, 15, 25, and 50. -30 to 130Â°F (-34.4 to 54.4Â°C) for 1950-02.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Rating\u003c\/td\u003e\n\u003ctd\u003e1\/4 hp @ 250V AC, 1\/8 hp @ 125V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService\u003c\/td\u003e\n\u003ctd\u003eAir and non-combustible, compatible gases.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e1\/8\" female NPT.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 3 (IP54), NEMA 7 and 9.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Differential Pressure Setting\u003c\/td\u003e\n\u003ctd\u003e0.4 in wc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Differential Pressure Setting\u003c\/td\u003e\n\u003ctd\u003e1.6 in wc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Switches\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eNEMA-3 Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure Rating\u003c\/td\u003e\n\u003ctd\u003e50 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125V AC, 250V AC, 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Type\u003c\/td\u003e\n\u003ctd\u003eDifferential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.25 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Line Connector Type\u003c\/td\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pressure Setting\u003c\/td\u003e\n\u003ctd\u003e0 in wc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure Setting\u003c\/td\u003e\n\u003ctd\u003e45 in wc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e140 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Setpoint Type\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Dwyer Instruments 1950-1-2F is a differential pressure switch with an explosion-proof and weatherproof aluminum housing. It is CE, CSA, FM, RoHS, and UL Listed with an IP54 rating, and is used for HVAC applications.\u003c\/p\u003e","brand":"Dwyer Instruments","offers":[{"title":"Default Title","offer_id":54073964101845,"sku":"1950-1-2F","price":465.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/195012F.jpg?v=1781971037","url":"https:\/\/proreplacementparts.com\/products\/1950-1-2f","provider":"Pro Replacement Parts","version":"1.0","type":"link"}