{"title":"Circuit Protection","description":"\u003cp\u003eShop Circuit Protection by manufacturer part number from brands including Square D, Eaton and Ge. Every listing shows the part number and its specifications, so you can match the part to your equipment before you order.\u003c\/p\u003e","products":[{"product_id":"hmcp150u4c","title":"HMCP150U4C Eaton Molded Case Circuit Breaker, HMCP Series, 150A, 3 Pole, 600V AC, 65kA at 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Eaton Motor Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell Motor:\u003c\/strong\u003e Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HMCP\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHMCP150U4C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eEaton Motor Starters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell Motor\u003c\/td\u003e \u003ctd\u003eStarters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHMCP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e130.7 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e57 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/J\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679150870\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton HMCP150U4C is a molded case circuit breaker from the HMCP series. It is rated for 150 A, 3 poles, 600V AC, and has a maximum AIR rating of 65kA at 600V AC. This thermal magnetic breaker has a fixed instantaneous trip, a 250A\/J frame size, and line\/load lug terminal connections.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67641621610709,"sku":"HMCP150U4C","price":2540.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJ-qcpEx.jpg?v=1791122230"},{"product_id":"hmcp150t4c","title":"HMCP150T4C Eaton Molded Case Circuit Breaker, HMCP Series, 150A, 3 Pole, 600V AC, 65kA at 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Eaton Motor Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell Motor:\u003c\/strong\u003e Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HMCP\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHMCP150T4C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eEaton Motor Starters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell Motor\u003c\/td\u003e \u003ctd\u003eStarters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHMCP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e126.7 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e34.6 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/J\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679150863\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton HMCP150T4C is a molded case circuit breaker from the HMCP series. It is rated for 150 A, 3 poles, and 600V AC with a maximum AIR rating of 65kA at 600V AC. This standard circuit breaker features a thermal magnetic trip type, a fixed instantaneous trip, and line\/load lug terminal connections.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67641679151317,"sku":"HMCP150T4C","price":2462.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJ-qcpEx_db9c25ae-c412-4a2f-a222-ce99db8e81c6.jpg?v=1791122350"},{"product_id":"qda32200","title":"QDA32200 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 200A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDA32200\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901417842\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDA32200 is a molded case circuit breaker from the QD series. It is rated for 200 A, 3 poles, and 240V AC, with a maximum AIR rating of 25kA at 240V AC. This thermal magnetic breaker has a fixed instantaneous trip, a 250A\/QD frame size, and an I-Line mounting style for use with I Line panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641685016789,"sku":"QDA32200","price":2443.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2E5_fo5oy.jpg?v=1791122380"},{"product_id":"qda32100","title":"QDA32100 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 100A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 100 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDA32100\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e100 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901702924\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDA32100 is a molded case circuit breaker from the QD series. It is rated for 100 A, 3 poles, and 240V AC, with a maximum AIR rating of 25kA at 240V AC. This thermal magnetic breaker has a fixed instantaneous trip, lug terminal connection, and is for use with I Line panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641685180629,"sku":"QDA32100","price":2443.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2E3-fo5oy.jpg?v=1791122381"},{"product_id":"nf430l2","title":"NF430L2 Square D Panelboard Interior, EDB, EDG, EDJ, 30 Spaces, 250A, 277\/480V, Convertible Main Lug, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eMain:\u003c\/strong\u003e Lug\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Series:\u003c\/strong\u003e EDB\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 250 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShort Circuit Current Rating:\u003c\/strong\u003e 100000 RMS Symmetrical\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 277\/480YV AC\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eNF430L2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003ePanelboard Interior\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Series\u003c\/td\u003e \u003ctd\u003eEDB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e250 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e100000 RMS Symmetrical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e277\/480YV AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material\u003c\/td\u003e \u003ctd\u003eAluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Enclosure\u003c\/td\u003e \u003ctd\u003e1D700 for Main Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003ctd\u003e6B429 for Main\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eBolt-On\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eNF Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e33 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e5 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e10 7\/16 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker\u003c\/td\u003e \u003ctd\u003eAdapter Kit 22P070\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMfr. No.\u003c\/td\u003e \u003ctd\u003eN250MKC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eConvertible, EDG, EDJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901871477\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D NF430L2 is a panelboard interior with 30 spaces, rated for 250 A at 277\/480YV AC, three-phase. It has an aluminum bus, a short circuit current rating of 100000 RMS symmetrical, and is for use with NF circuit breakers. This convertible main lug unit measures 33 in high, 10 7\/16 in wide, and 5 3\/4 in deep.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641693896917,"sku":"NF430L2","price":2423.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0FOoyfo5oz.jpg?v=1791122414"},{"product_id":"jdl36225","title":"JDL36225 Square D Molded Case Circuit Breaker, POWERPACT J Series, 225A, 3 Pole, 600V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 225 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e JD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,250 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 1,125 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eJDL36225\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e225 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eJD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,250 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eAdjustable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/JD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e7.52 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.12 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901623175\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D JDL36225 is a molded case circuit breaker from the JD series. It is rated for 225 A, 600V AC, and 250V DC, with a maximum AIR rating of 25kA at 240V AC. This three-pole, thermal magnetic unit has an adjustable instantaneous trip and line\/load lug terminal connections.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641693929685,"sku":"JDL36225","price":2422.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z_8-L-fo5oy.jpg?v=1791122415"},{"product_id":"nf430l1c","title":"NF430L1C Square D Panelboard Interior, EDB, EDG, EDJ, 30 Spaces, 125A, 277\/480V, Convertible Main Lug, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eMain:\u003c\/strong\u003e Lug\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Series:\u003c\/strong\u003e EDB\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShort Circuit Current Rating:\u003c\/strong\u003e 100000 RMS Symmetrical\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 277\/480YV AC\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eNF430L1C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003ePanelboard Interior\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Series\u003c\/td\u003e \u003ctd\u003eEDB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e100000 RMS Symmetrical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e277\/480YV AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Enclosure\u003c\/td\u003e \u003ctd\u003e1D691 for Main Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaker\u003c\/td\u003e \u003ctd\u003e1D698 for Main\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eBolt-On\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eNF Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e27 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e5 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e10 7\/16 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker\u003c\/td\u003e \u003ctd\u003eAdapter Kit 22P069\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eConvertible, EDG, EDJ, 48N065\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901871446\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D NF430L1C is a panelboard interior with a convertible main lug and 30 spaces. It is rated for 125 A at 277\/480YV AC, three-phase, with a short circuit current rating of 100000 RMS symmetrical. This unit has a copper bus, bolt-on circuit breaker type, and measures 27 in high, 10 7\/16 in wide, and 5 3\/4 in deep.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641721028821,"sku":"NF430L1C","price":2360.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0FOoxfo5oy.jpg?v=1791122548"},{"product_id":"hgl36100u31x","title":"HGL36100U31X Square D Molded Case Circuit Breaker, POWERPACT H Series, 100A, 3 Pole, 600V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 100 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HG\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 60 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 100 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHGL36100U31X\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e100 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e60 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e100 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eMicrologic Standard W LI Functionality\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Box\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eAdjustable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.1 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901229049\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HGL36100U31X is a molded case circuit breaker from the HG series with three poles and a 100 A rating. It is rated for 600V AC and 250V DC, with a maximum AIR rating of 65kA at 240V AC. This thermal magnetic breaker has adjustable instantaneous trip, Micrologic Standard W LI functionality, and a 150A\/HG frame size.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641793413333,"sku":"HGL36100U31X","price":2282.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z_s5x_icpEx.jpg?v=1791122721"},{"product_id":"tm30420r","title":"TM30420R Ge Load Center, TM304, THQL, 30 Spaces, 200A, 120\/208V, Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/208V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e THQL\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover:\u003c\/strong\u003e Combination Flush\/Surface\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug Main:\u003c\/strong\u003e Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eTM30420R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eGe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e120\/208V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eTHQL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover\u003c\/td\u003e \u003ctd\u003eCombination Flush\/Surface\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug Main\u003c\/td\u003e \u003ctd\u003eCircuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eTM304\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e36.25 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e12.88 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e5 1\/2 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With GE\u003c\/td\u003e \u003ctd\u003eTHQL Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material\u003c\/td\u003e \u003ctd\u003eAluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e22kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e3R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style\u003c\/td\u003e \u003ctd\u003eTop Hinge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Closure Method\u003c\/td\u003e \u003ctd\u003eLatch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e783164190250\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Ge TM30420R is a load center with 30 spaces, a 200 A rating, and 120\/208V AC three-phase operation. It uses THQL circuit breakers and includes a main circuit breaker with a combination flush\/surface enclosure cover. The unit has an aluminum bus, a 22kA short circuit current rating, a NEMA 3R enclosure, and measures 36.25 in high, 12.88 in wide, and 5 1\/2 in deep.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Ge","offers":[{"title":"Default Title","offer_id":67641798983893,"sku":"TM30420R","price":2152.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0qLFtkcpIx.jpg?v=1791122752"},{"product_id":"hfd3050","title":"HFD3050 Eaton Molded Case Circuit Breaker, HFD Series, 50A, 3 Pole, 600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 50 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Allen Bradley MCC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell:\u003c\/strong\u003e Automation Enclosed Control\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HFD\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHFD3050\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e50 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eAllen Bradley MCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell\u003c\/td\u003e \u003ctd\u003eAutomation Enclosed Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHFD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e225 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e15 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Load Side\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eEaton MCC Eaton, Switchboard, Westinghouse\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679175859\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton HFD3050 is a molded case circuit breaker from the HFD series rated for 50 A and 600V AC, with a maximum AIR rating of 100kA at 240V AC. It is a three-pole, thermal magnetic unit with a fixed instantaneous trip and a DC voltage rating of 250V DC. The breaker has a high amp trip setting of 225 A and a low amp trip setting of 15 A.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67641857900757,"sku":"HFD3050","price":2207.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJzpcpEx.jpg?v=1791122882"},{"product_id":"qda32150","title":"QDA32150 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 150A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDA32150\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901702917\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDA32150 is a molded case circuit breaker from the QD series. It is rated for 150 A and 240V AC, with a maximum AIR rating of 25kA at 240V AC. This three-pole, thermal magnetic breaker has a 250A\/QD frame size and is for use with I-Line panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641863405781,"sku":"QDA32150","price":2199.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2E3-fo5oy_da1b13f1-6e8d-4ef6-8609-426f8e2c8e35.jpg?v=1791122895"},{"product_id":"qda32125","title":"QDA32125 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 125A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDA32125\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901702900\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDA32125 is a molded case circuit breaker from the QD series. It is rated for 125 A and 240V AC with a maximum AIR rating of 25kA at 240V AC. This three-pole, thermal magnetic unit has a 250A\/QD frame size and is for use with I-Line panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641863438549,"sku":"QDA32125","price":2199.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2E3-fo5oy_526b5761-fcee-4176-a235-7503479e7b95.jpg?v=1791122895"},{"product_id":"bja36015","title":"BJA36015 Square D Molded Case Circuit Breaker, POWERPACT B Series, 15A, 3 Pole, 347\/600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 15 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Electrical Distribution Equipment\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIndustrial Control:\u003c\/strong\u003e Panels\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e BJA\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eBJA36015\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e15 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e690V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eElectrical Distribution Equipment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIndustrial Control\u003c\/td\u003e \u003ctd\u003ePanels\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eBJA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eAl Mechanical Lug OFF End\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnd\u003c\/td\u003e \u003ctd\u003eI-Line ON\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/BJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e5.39 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901022749\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D BJA36015 is a molded case circuit breaker from the POWERPACT B Series. It is a 15 A, 3 pole, three-phase unit with a 690V AC voltage rating and a maximum AIR rating of 100kA at 120\/240V AC. This standard circuit breaker uses a thermal magnetic trip type with a fixed instantaneous trip and an I-Line mounting style.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641894011093,"sku":"BJA36015","price":2169.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1wt_zqcpEx.jpg?v=1791122962"},{"product_id":"la400r","title":"LA400R Square D Circuit Breaker Enclosure, LA, 3 Spaces, 400A, Main Circuit Breaker","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eMaterial:\u003c\/strong\u003e Steel\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNEMA Rating:\u003c\/strong\u003e 3R\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eExterior Height:\u003c\/strong\u003e 44 in\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eExterior Width:\u003c\/strong\u003e 15.38 in\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eExterior Depth:\u003c\/strong\u003e 7.88 in\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With Square D:\u003c\/strong\u003e LAL and LHL Circuit Breakers\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eLA400R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eCircuit Breaker Enclosure\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaterial\u003c\/td\u003e \u003ctd\u003eSteel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNEMA Rating\u003c\/td\u003e \u003ctd\u003e3R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExterior Height\u003c\/td\u003e \u003ctd\u003e44 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExterior Width\u003c\/td\u003e \u003ctd\u003e15.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExterior Depth\u003c\/td\u003e \u003ctd\u003e7.88 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eLAL and LHL Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePowder Coated\u003c\/td\u003e \u003ctd\u003eFinish\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting Style\u003c\/td\u003e \u003ctd\u003eSurface\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLocation\u003c\/td\u003e \u003ctd\u003eOutdoor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. Operating Temp.\u003c\/td\u003e \u003ctd\u003e140 Degrees F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin. Operating Temp.\u003c\/td\u003e \u003ctd\u003e32 Degrees F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConduit\u003c\/td\u003e \u003ctd\u003eProvision 1\/2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style\u003c\/td\u003e \u003ctd\u003eTop Hinge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eGray, 3\/4, 1, 1 1\/4, 1 1\/2, 2, 2 1\/2, 3, 3 1\/2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901508021\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D LA400R is a steel circuit breaker enclosure with a NEMA 3R rating for outdoor use. It provides three spaces and is rated for 400 A, with a surface mounting style and a top hinge cover attachment. The enclosure has a powder coated finish and exterior dimensions of 44 in height, 15.38 in width, and 7.88 in depth.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641901809877,"sku":"LA400R","price":2155.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-5M1wfo5oy.jpg?v=1791122991"},{"product_id":"hfd3060","title":"HFD3060 Eaton Molded Case Circuit Breaker, HFD Series, 60A, 3 Pole, 600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 60 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Allen Bradley MCC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell:\u003c\/strong\u003e Automation Enclosed Control\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HFD\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHFD3060\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e60 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eAllen Bradley MCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell\u003c\/td\u003e \u003ctd\u003eAutomation Enclosed Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHFD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e225 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e15 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Load Side\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eEaton MCC Eaton, Switchboard, Westinghouse\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679175866\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton HFD3060 is a molded case circuit breaker from the HFD series. It is rated for 60 A, 3 poles, and 600V AC, with a maximum AIR rating of 100kA at 240V AC. This standard, thermal magnetic breaker has a fixed instantaneous trip and a DC voltage rating of 250V DC.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67641912099029,"sku":"HFD3060","price":2129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJzpcpEx_3051a7a3-f81c-40f4-8070-aea03c1b0557.jpg?v=1791123068"},{"product_id":"qo330mq125rb","title":"QO330MQ125RB Square D Load Center, QO, 30 Spaces, 125A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover Surface:\u003c\/strong\u003e Cover\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO330MQ125RB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover Surface\u003c\/td\u003e \u003ctd\u003eCover\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.77 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4 1\/2 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e3R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style Side\u003c\/td\u003e \u003ctd\u003eHinge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290599\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO330MQ125RB is a QO series load center with 30 spaces, rated for 125 A and 208Y\/120\/240V AC in a 3-phase configuration. It features a convertible main circuit breaker, a copper bus, and a NEMA 3R enclosure with a side-hinge cover. The unit measures 39.38 in high, 14.77 in wide, and 4 1\/2 in deep, and has a short circuit current rating of 25kA.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641919307989,"sku":"QO330MQ125RB","price":2107.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2CIxfo5oy.jpg?v=1791123115"},{"product_id":"qo330mq150rb","title":"QO330MQ150RB Square D Load Center, QO, 30 Spaces, 150A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover Surface:\u003c\/strong\u003e Cover\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO330MQ150RB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover Surface\u003c\/td\u003e \u003ctd\u003eCover\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.77 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4 1\/2 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e3R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style Side\u003c\/td\u003e \u003ctd\u003eHinge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290605\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO330MQ150RB is a QO series load center with 30 spaces and a 150 A rating. It operates at 208Y\/120\/240V AC, is a 3-phase unit, and includes a convertible main circuit breaker. The enclosure has a NEMA 3R rating, a copper bus, and measures 39.38 inches high by 14.77 inches wide by 4 1\/2 inches deep.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67641947816149,"sku":"QO330MQ150RB","price":2042.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2CIxfo5oy_bb67167b-163e-455a-b2c0-5fb67cc758ef.jpg?v=1791123303"},{"product_id":"qo330mq150","title":"QO330MQ150 Square D Load Center, QO, 30 Spaces, 150A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover:\u003c\/strong\u003e Order Separately\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO330MQ150\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover\u003c\/td\u003e \u003ctd\u003eOrder Separately\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.25 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Flush Cover\u003c\/td\u003e \u003ctd\u003e3XB93\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290537\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO330MQ150 is a QO series load center with 30 spaces and a 150 A rating for 208Y\/120\/240V AC, 3-phase systems. It has a convertible main circuit breaker configuration, a tin-plated copper bus, and a short circuit current rating of 25kA. The enclosure is NEMA 1 rated, measures 39.38 in high by 14.25 in wide by 3 3\/4 in deep, and the cover is ordered separately.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647271370965,"sku":"QO330MQ150","price":1912.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0J0w0fo5oz.jpg?v=1791173172"},{"product_id":"bja36050","title":"BJA36050 Square D Molded Case Circuit Breaker, POWERPACT B Series, 50A, 3 Pole, 347\/600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 50 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Electrical Distribution Equipment\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIndustrial Control:\u003c\/strong\u003e Panels\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e BJA\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eBJA36050\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e50 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e690V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eElectrical Distribution Equipment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIndustrial Control\u003c\/td\u003e \u003ctd\u003ePanels\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eBJA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eAl Mechanical Lug OFF End\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnd\u003c\/td\u003e \u003ctd\u003eI-Line ON\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/BJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e5.39 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901025863\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D BJA36050 is a molded case circuit breaker from the BJA series. It is rated for 50 A, three poles, and 690V AC, with a maximum AIR rating of 100kA at 120\/240V AC. This standard circuit breaker uses a thermal magnetic trip type with a fixed instantaneous trip and an I-Line mounting style.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647273140437,"sku":"BJA36050","price":2008.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1wt_zqcpEx_089ec66f-8232-4dac-a846-30cafa579ec1.jpg?v=1791173187"},{"product_id":"nf418l1c","title":"NF418L1C Square D Panelboard Interior, EDB, EDG, EDJ, 18 Spaces, 125A, 277\/480V, Convertible Main Lug, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eMain:\u003c\/strong\u003e Lug\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Series:\u003c\/strong\u003e EDB\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShort Circuit Current Rating:\u003c\/strong\u003e 100000 RMS Symmetrical\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 18\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 277\/480YV AC\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eNF418L1C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003ePanelboard Interior\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Series\u003c\/td\u003e \u003ctd\u003eEDB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e100000 RMS Symmetrical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e18\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e277\/480YV AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Enclosure\u003c\/td\u003e \u003ctd\u003e1D687 for Main Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaker\u003c\/td\u003e \u003ctd\u003e6B429 for Main\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eBolt-On\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eNF Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e21 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e5 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e10 7\/16 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Flush Cover\u003c\/td\u003e \u003ctd\u003e3TX77 for Main Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaker\u003c\/td\u003e \u003ctd\u003e3TX81 for Main\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eConvertible, EDG, EDJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901871293\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D NF418L1C is a panelboard interior with a convertible main lug configuration. It provides 18 spaces and is rated for 125 A at 277\/480YV AC, three phase. This unit has a copper bus, a short circuit current rating of 100000 RMS Symmetrical, and is for use with NF circuit breakers.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647274025173,"sku":"NF418L1C","price":2007.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0FOovfo5oy.jpg?v=1791173192"},{"product_id":"jdl26150","title":"JDL26150 Square D Molded Case Circuit Breaker, POWERPACT J Series, 150A, 2 Pole, 600V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e JD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 1,500 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 750 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eJDL26150\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eJD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,500 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e750 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eSingle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eAdjustable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eNot Applicable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/JD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e7.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901955771\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D JDL26150 is a molded case circuit breaker from the JD series. It is a 2-pole, 150 A unit rated for 600V AC and 250V DC, with a maximum AIR rating of 25kA at 240V AC. This thermal magnetic breaker has an adjustable instantaneous trip with low and high amp trip settings of 750 A and 1,500 A.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647274942677,"sku":"JDL26150","price":2004.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z_8-5yfo5oy.jpg?v=1791173198"},{"product_id":"pdg23m0175tffl","title":"PDG23M0175TFFL Eaton Molded Case Circuit Breaker, 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 175 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 480V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Current-Limiting Breakers\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eDC:\u003c\/strong\u003e Breakers 125 to 750 V DC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eEngine:\u003c\/strong\u003e Generator Breakers 15 to 1200 Amperes\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003ePDG23M0175TFFL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e175 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 480V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eCurrent-Limiting Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC\u003c\/td\u003e \u003ctd\u003eBreakers 125 to 750 V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEngine\u003c\/td\u003e \u003ctd\u003eGenerator Breakers 15 to 1200 Amperes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMining Breakers upto\u003c\/td\u003e \u003ctd\u003e1100 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreakers\u003c\/td\u003e \u003ctd\u003eNavy\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e175 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e175 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Load Side\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679858226\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0175TFFL is a molded case circuit breaker rated for 175 A and 600V AC. It has three poles, a thermal magnetic trip type, and a maximum AIR rating of 65kA at 480V AC. The terminal connection on the load side is a lug.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67647278809301,"sku":"PDG23M0175TFFL","price":1992.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/4638e760-5c2f-4e31-8032-1ededcd7325f.jpg?v=1791173225"},{"product_id":"hdl26150","title":"HDL26150 Square D Molded Case Circuit Breaker, POWERPACT H Series, 150A, 2 Pole, 600V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 1,700 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 900 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHDL26150\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,700 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e900 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eSingle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eNon-Applicable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e2.74 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901577850\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HDL26150 is a molded case circuit breaker from the HD series. It is rated for 150 A, 2 poles, and 600V AC, with a maximum AIR rating of 25kA at 240V AC. This thermal magnetic unit has a fixed instantaneous trip and line\/load lug terminal connections.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647281725653,"sku":"HDL26150","price":1982.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z_8-6_fo5oy.jpg?v=1791173254"},{"product_id":"bja36060","title":"BJA36060 Square D Molded Case Circuit Breaker, POWERPACT B Series, 60A, 3 Pole, 347\/600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 60 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Electrical Distribution Equipment\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIndustrial Control:\u003c\/strong\u003e Panels\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e BJA\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eBJA36060\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e60 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e690V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eElectrical Distribution Equipment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIndustrial Control\u003c\/td\u003e \u003ctd\u003ePanels\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eBJA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eAl Mechanical Lug OFF End\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnd\u003c\/td\u003e \u003ctd\u003eI-Line ON\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/BJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e5.39 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901010777\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D BJA36060 is a molded case circuit breaker from the POWERPACT B Series. It is a 3-pole, 60 A unit with a 690V AC voltage rating and a maximum AIR rating of 100kA at 120\/240V AC. This standard circuit breaker features thermal magnetic trip, fixed instantaneous trip, and an I-Line mounting style.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647290638549,"sku":"BJA36060","price":1956.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1wt_zqcpEx_2e19073f-3f1d-4279-bb89-eebc879e47db.jpg?v=1791173327"},{"product_id":"hga36080","title":"HGA36080 Square D Molded Case Circuit Breaker, POWERPACT H Series, 80A, 3 Pole, 600V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 80 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HG\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 1,450 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHGA36080\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e80 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,450 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e800 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e9.73 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.48 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4.8 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901507314\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HGA36080 is a molded case circuit breaker from the HG series. It is a three-pole, 600V AC unit rated for 80 A with a maximum AIR rating of 65kA at 240V AC. This thermal magnetic breaker has a fixed instantaneous trip, lug terminal connection, and is for use with I Line panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647291424981,"sku":"HGA36080","price":1955.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2C60fo5oy.jpg?v=1791173336"},{"product_id":"nf430l1","title":"NF430L1 Square D Panelboard Interior, EDB, EDG, EDJ, 30 Spaces, 125A, 277\/480V, Convertible Main Lug, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eMain:\u003c\/strong\u003e Lug\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Series:\u003c\/strong\u003e EDB\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShort Circuit Current Rating:\u003c\/strong\u003e 100000 RMS Symmetrical\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 277\/480YV AC\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eNF430L1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003ePanelboard Interior\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Series\u003c\/td\u003e \u003ctd\u003eEDB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e100000 RMS Symmetrical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e277\/480YV AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material\u003c\/td\u003e \u003ctd\u003eAluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Enclosure\u003c\/td\u003e \u003ctd\u003e1D691 for Main Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaker\u003c\/td\u003e \u003ctd\u003e1D698 for Main\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eBolt-On\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eNF Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e27 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e5 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e10 7\/16 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker\u003c\/td\u003e \u003ctd\u003eAdapter Kit 22P069\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eConvertible, EDG, EDJ, 48N065\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901871439\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D NF430L1 is a panelboard interior with 30 spaces and a 125 A rating for 277\/480YV AC three-phase systems. It features an aluminum bus, a convertible main lug, and is for use with NF circuit breakers. The unit measures 27 inches high, 10 7\/16 inches wide, and 5 3\/4 inches deep, with a short circuit current rating of 100000 RMS symmetrical.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647300993237,"sku":"NF430L1","price":1928.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0FOowfo5oz.jpg?v=1791173406"},{"product_id":"qo342mq200rb","title":"QO342MQ200RB Square D Load Center, QO, 42 Spaces, 200A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 42\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover Surface:\u003c\/strong\u003e Cover\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO342MQ200RB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e42\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover Surface\u003c\/td\u003e \u003ctd\u003eCover\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.77 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4 1\/2 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e3R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style Side\u003c\/td\u003e \u003ctd\u003eHinge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290636\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO342MQ200RB is a QO series load center with 42 spaces and a 200 A rating. It operates at 208Y\/120\/240V AC, is three-phase, and has a convertible main circuit breaker. The enclosure is NEMA 3R rated with a copper bus and a short circuit current rating of 25kA.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647302205653,"sku":"QO342MQ200RB","price":1925.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2CJzfo5oy.jpg?v=1791173417"},{"product_id":"thed136030wl","title":"THED136030WL Ge Molded Case Circuit Breaker, THED Series, 30A, 3 Pole, 600V AC, 18kA at 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 30 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 14kA at 277V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With GE:\u003c\/strong\u003e Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e THED\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e Standard\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eTHED136030WL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eGe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e30 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e14kA at 277V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With GE\u003c\/td\u003e \u003ctd\u003ePanelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eTHED\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e125\/250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/THED\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003ePlug In Panelboard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.31 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.13 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4.09 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin. Wire Size\u003c\/td\u003e \u003ctd\u003e14 AWG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e783164062786\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Ge THED136030WL is a molded case circuit breaker from the THED series. It is rated for 30 A, 3 poles, and 600V AC, with a maximum AIR rating of 14kA at 277V AC. This standard thermal magnetic breaker has a 150A\/THED frame size and plug-in panelboard mounting.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Ge","offers":[{"title":"Default Title","offer_id":67647302500565,"sku":"THED136030WL","price":1922.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z3yM9xfo5oy.jpg?v=1791173422"},{"product_id":"hgl36000s15","title":"HGL36000S15 Square D Molded Case Circuit Breaker, POWERPACT H Series, 150A, 3 Pole, 600V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HG\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,250 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 1,125 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHGL36000S15\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,250 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eShunt Trip\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.12 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4.36 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901433958\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HGL36000S15 is a molded case circuit breaker from the HG series. It is a 3-pole, three-phase shunt trip unit with a thermal magnetic trip type and a 150A\/HG frame size. This breaker is rated for 150 A, 600V AC, 250V DC, and has a maximum AIR rating of 65kA at 240V AC. It features lug terminal connections and a fixed instantaneous trip.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647318294741,"sku":"HGL36000S15","price":1879.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z_80zzfo5oy.jpg?v=1791173549"},{"product_id":"ed42b030","title":"ED42B030 Siemens Molded Case Circuit Breaker, ED4 Series, 30A, 2 Pole, 480V AC, 18kA at 480V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 30 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 480V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 18kA at 480V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e SB Switchboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePanelboards:\u003c\/strong\u003e Sentron\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e ED4\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eED42B030\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSiemens\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e30 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e480V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e18kA at 480V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eSB Switchboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePanelboards\u003c\/td\u003e \u003ctd\u003eSentron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eED4\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e30 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e30 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Load Side\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eSingle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eAny\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/ED\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eLug In Panelboard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e783643209244\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Siemens ED42B030 is a molded case circuit breaker from the ED4 series. It is rated for 30 A, 2 poles, 480V AC, and has a maximum AIR rating of 18kA at 480V AC. This standard thermal magnetic breaker has a 125A\/ED frame size and is for use with SB switchboards and Sentron panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67647320752341,"sku":"ED42B030","price":1808.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0_B3_fo5oy.jpg?v=1791173563"},{"product_id":"bja36020","title":"BJA36020 Square D Molded Case Circuit Breaker, POWERPACT B Series, 20A, 3 Pole, 347\/600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 20 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Electrical Distribution Equipment\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIndustrial Control:\u003c\/strong\u003e Panels\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e BJA\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eBJA36020\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e20 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e690V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eElectrical Distribution Equipment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIndustrial Control\u003c\/td\u003e \u003ctd\u003ePanels\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eBJA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eAl Mechanical Lug OFF End\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnd\u003c\/td\u003e \u003ctd\u003eI-Line ON\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/BJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e5.39 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901010852\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D BJA36020 is a molded case circuit breaker from the POWERPACT B Series. It is a 3-pole, 20 A unit rated for 347\/600V AC with a maximum AIR rating of 100kA at 120\/240V AC. This thermal magnetic breaker has a 125A\/BJ frame size and I-Line mounting.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647322751189,"sku":"BJA36020","price":1870.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1wt_zqcpEx_ea038ffd-135a-4f81-92d1-40867abe31f4.jpg?v=1791173575"},{"product_id":"bga34125y","title":"BGA34125Y Square D Molded Case Circuit Breaker, POWERPACT B Series, 125A, 3 Pole, 277\/480V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 525V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Electrical Distribution Equipment\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIndustrial Control:\u003c\/strong\u003e Panels\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e BGA\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eBGA34125Y\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e525V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eElectrical Distribution Equipment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIndustrial Control\u003c\/td\u003e \u003ctd\u003ePanels\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eBGA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eAl Mechanical Lug OFF End\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnd\u003c\/td\u003e \u003ctd\u003eI-Line ON\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/BG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e5.39 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901069553\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D BGA34125Y is a molded case circuit breaker from the BGA series. It is a three-pole, three-phase unit rated for 125 A and 525V AC, with a maximum AIR rating of 100kA at 240V AC. This standard circuit breaker features thermal magnetic trip, a fixed instantaneous trip, an I-Line ON end, and an Al mechanical lug OFF end terminal connection.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647325176021,"sku":"BGA34125Y","price":1868.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1wt_ylcpEx.jpg?v=1791173589"},{"product_id":"s48907","title":"S48907 Square D Molded Case Circuit Breakers","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e LA-\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breakers:\u003c\/strong\u003e and Q4-Frame Molded Case\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eR:\u003c\/strong\u003e PowerPact\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eStandards:\u003c\/strong\u003e CSA, UL Listed\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eS48907\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eLA-\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breakers\u003c\/td\u003e \u003ctd\u003eand Q4-Frame Molded Case\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eR\u003c\/td\u003e \u003ctd\u003ePowerPact\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStandards\u003c\/td\u003e \u003ctd\u003eCSA, UL Listed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eLH-, PowerPacT P, MicroLogic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901709237\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D S48907 is a molded case circuit breaker intended for use with LA-, LH-, and Q4-Frame molded case circuit breakers, as well as PowerPacT P and MicroLogic units. This item is CSA and UL Listed.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647325569237,"sku":"S48907","price":1866.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/34b1b8f6-a718-453c-9b39-825702405acd.jpg?v=1791173591"},{"product_id":"hgl36070","title":"HGL36070 Square D Molded Case Circuit Breaker, POWERPACT H Series, 70A, 3 Pole, 600V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 70 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HG\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 1,450 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 800 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHGL36070\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e70 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,450 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e800 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250\/500V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.12 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4.36 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901598787\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HGL36070 is a molded case circuit breaker from the HG series. It is a three-pole, 70 A unit rated for 600V AC and 250\/500V DC, with a maximum AIR rating of 65kA at 240V AC. This thermal magnetic breaker has fixed instantaneous trip settings from 800 A to 1,450 A and uses line\/load lug terminal connections.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647334875349,"sku":"HGL36070","price":1832.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z_8-I_fo5oy.jpg?v=1791173644"},{"product_id":"hga260402","title":"HGA260402 Square D Molded Case Circuit Breaker, POWERPACT H Series, 40A, 2 Pole, 600V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 40 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HG\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 850 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHGA260402\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e40 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e850 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250\/500\/600V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eSingle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eAC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e9.73 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e2.94 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901539612\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HGA260402 is a molded case circuit breaker from the HG series for use with I-Line panelboards. It is a 2-pole, 40 A unit rated for 600V AC with a maximum AIR rating of 65kA at 240V AC. This standard circuit breaker has a thermal magnetic trip type, fixed instantaneous trip, lug terminal connection, and a frame size of 150A\/HG.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647336448213,"sku":"HGA260402","price":1849.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2BL0fo5oy.jpg?v=1791173652"},{"product_id":"fd3080","title":"FD3080 Eaton Molded Case Circuit Breaker, FD Series, 80A, 3 Pole, 600V AC, 65kA at 240\/277V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 80 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240\/277V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Allen Bradley MCC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell:\u003c\/strong\u003e Automation Enclosed Control\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e FD\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eFD3080\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e80 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240\/277V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eAllen Bradley MCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell\u003c\/td\u003e \u003ctd\u003eAutomation Enclosed Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eFD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e225 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e15 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Load Side\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eEaton MCC Eaton, Switchboard, Westinghouse\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679305744\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton FD3080 is a molded case circuit breaker from the FD series. It is rated for 80 A, 3 poles, 600V AC, and 250V DC, with a maximum AIR rating of 65kA at 240\/277V AC. This standard thermal magnetic breaker has a fixed instantaneous trip, a low amp trip setting of 15 A, a high amp trip setting of 225 A, and a lug terminal connection on the load side.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67647343362261,"sku":"FD3080","price":1840.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJujcpEx.jpg?v=1791173680"},{"product_id":"fd3060","title":"FD3060 Eaton Molded Case Circuit Breaker, FD Series, 60A, 3 Pole, 600V AC, 65kA at 240\/277V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 60 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240\/277V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Allen Bradley MCC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell:\u003c\/strong\u003e Automation Enclosed Control\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e FD\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eFD3060\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e60 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240\/277V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eAllen Bradley MCC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell\u003c\/td\u003e \u003ctd\u003eAutomation Enclosed Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eFD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e225 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e15 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection Load Side\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eEaton MCC Eaton, Switchboard, Westinghouse\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679305713\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton FD3060 is a molded case circuit breaker from the FD series. It is rated for 60 A, three poles, 600V AC, and 250V DC, with a maximum AIR rating of 65kA at 240\/277V AC. This standard thermal magnetic breaker has a fixed instantaneous trip and a lug terminal connection on the load side.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67647346475221,"sku":"FD3060","price":1831.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJujcpEx_1dc2d54d-db97-4602-ad0e-4777a3164458.jpg?v=1791173697"},{"product_id":"thed136020wl","title":"THED136020WL Ge Molded Case Circuit Breaker, THED Series, 20A, 3 Pole, 600V AC, 18kA at 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 20 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 14kA at 277V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With GE:\u003c\/strong\u003e Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e THED\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e Standard\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eTHED136020WL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eGe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e20 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e14kA at 277V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With GE\u003c\/td\u003e \u003ctd\u003ePanelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eTHED\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e125\/250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/THED\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003ePlug In Panelboard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.31 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.13 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4.09 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin. Wire Size\u003c\/td\u003e \u003ctd\u003e14 AWG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e783164062762\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Ge THED136020WL is a molded case circuit breaker from the THED series rated for 20 A and 600V AC. This three-pole, thermal magnetic unit has a plug-in panelboard mounting style and line\/load lug terminal connections. It measures 6.31 in high, 4.13 in wide, and 4.09 in deep, with a maximum AIR rating of 14kA at 277V AC.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Ge","offers":[{"title":"Default Title","offer_id":67647349850325,"sku":"THED136020WL","price":1826.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z3yM9xfo5oy_c132ab32-d994-4a62-be7f-8ab0fd7e9475.jpg?v=1791173709"},{"product_id":"qo330mq125","title":"QO330MQ125 Square D Load Center, QO, 30 Spaces, 125A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 125 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover:\u003c\/strong\u003e Order Separately\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO330MQ125\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e125 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover\u003c\/td\u003e \u003ctd\u003eOrder Separately\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.25 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Flush Cover\u003c\/td\u003e \u003ctd\u003e3XB93\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290520\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO330MQ125 is a QO series load center with 30 spaces and a 125 A rating at 208Y\/120\/240V AC, 3 phase. It features a convertible main circuit breaker configuration and a tin-plated copper bus with a short circuit current rating of 25kA. The enclosure has a NEMA 1 rating and measures 39.38 in high, 14.25 in wide, and 3 3\/4 in deep; the cover is ordered separately.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647356338389,"sku":"QO330MQ125","price":1816.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2CG_fo5oy.jpg?v=1791173741"},{"product_id":"hmcp070m2c","title":"HMCP070M2C Eaton Molded Case Circuit Breaker, HMCP Series, 70A, 3 Pole, 600V AC, 65kA at 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 70 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Eaton Motor Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell Motor:\u003c\/strong\u003e Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HMCP\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHMCP070M2C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e70 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eEaton Motor Starters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell Motor\u003c\/td\u003e \u003ctd\u003eStarters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHMCP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e59.1 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e16.1 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/J\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679150849\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton HMCP070M2C is a molded case circuit breaker from the HMCP series with a 70 A rating and three poles. It is rated for 600V AC and 250V DC, with a maximum AIR rating of 65kA at 600V AC. This thermal magnetic breaker has a fixed instantaneous trip, a low amp trip setting of 16.1 A, a high amp trip setting of 59.1 A, and line\/load lug terminal connections.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67647364694229,"sku":"HMCP070M2C","price":1806.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJ-qcpEx_f70f43e6-8c14-491e-8d81-fac13a1922cc.jpg?v=1791173782"},{"product_id":"qdl32225","title":"QDL32225 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 225A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 225 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 1,200 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDL32225\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e225 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3.93 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901672470\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDL32225 is a molded case circuit breaker from the QD series. It is a 3-pole, 240V AC unit rated for 225 A with a maximum AIR rating of 25kA at 240V AC. This thermal magnetic breaker has a fixed instantaneous trip, lug terminal connection, and a 250A\/QD frame size.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647370461397,"sku":"QDL32225","price":1797.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-5M3zfo5oy.jpg?v=1791173813"},{"product_id":"hmcp100r3c","title":"HMCP100R3C Eaton Molded Case Circuit Breaker, HMCP Series, 100A, 3 Pole, 600V AC, 65kA at 600V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 100 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Eaton Motor Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRockwell Motor:\u003c\/strong\u003e Starters\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HMCP\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHMCP100R3C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eEaton\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e100 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eEaton Motor Starters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRockwell Motor\u003c\/td\u003e \u003ctd\u003eStarters\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHMCP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e84.5 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e23 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLine\/Load Lug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/J\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e786679150856\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Eaton HMCP100R3C is a molded case circuit breaker from the HMCP series with a 100 A rating and three poles. It has a 600V AC voltage rating, a 65kA maximum AIR rating at 600V AC, and a 250V DC rating. This standard circuit breaker features thermal magnetic trip type, a fixed instantaneous trip, line\/load lug terminal connections, and a 250A\/J frame size.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":67647375212757,"sku":"HMCP100R3C","price":1792.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1uBJ-qcpEx_9ab3ce11-c15a-4deb-bf89-f0fc40b8940b.jpg?v=1791173836"},{"product_id":"hga260151","title":"HGA260151 Square D Molded Case Circuit Breaker, POWERPACT H Series, 15A, 2 Pole, 600V AC, 65kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 15 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 65kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e I Line Panelboards\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e HG\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 750 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eHGA260151\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e15 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e600V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e65kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eI Line Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eHG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e750 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e350 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003e250\/500\/600V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eSingle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eAB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e150A\/HG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eI-Line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e9.73 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e2.94 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901539674\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D HGA260151 is a molded case circuit breaker from the HG series. It is rated for 15 A, 2 poles, and 600V AC, with a maximum AIR rating of 65kA at 240V AC. This thermal magnetic breaker has a fixed instantaneous trip, lug terminal connections, and is for use with I Line panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647386583253,"sku":"HGA260151","price":1780.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2BL0fo5oy_0c76e339-d21b-4b8e-9428-e9d0e163f982.jpg?v=1791173884"},{"product_id":"qo330mq200rb","title":"QO330MQ200RB Square D Load Center, QO, 30 Spaces, 200A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover Surface:\u003c\/strong\u003e Cover\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO330MQ200RB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover Surface\u003c\/td\u003e \u003ctd\u003eCover\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.77 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4 1\/2 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e3R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style Side\u003c\/td\u003e \u003ctd\u003eHinge\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290612\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO330MQ200RB is a three-phase QO series load center with 30 spaces and a 200 A rating at 208Y\/120\/240V AC. It includes a convertible main circuit breaker and a cover with a side hinge. The enclosure has a NEMA 3R rating, a tin-plated copper bus, and a short circuit current rating of 25kA.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647387697365,"sku":"QO330MQ200RB","price":1779.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2CJufo5oy.jpg?v=1791173889"},{"product_id":"bjl36020","title":"BJL36020 Square D Molded Case Circuit Breaker, POWERPACT B Series, 20A, 3 Pole, 347\/600V AC, 100kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 20 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 690V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 100kA at 120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFor Use With:\u003c\/strong\u003e Electrical Distribution Equipment\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIndustrial Control:\u003c\/strong\u003e Panels\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e BJL\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eBJL36020\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e20 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e690V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e100kA at 120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With\u003c\/td\u003e \u003ctd\u003eElectrical Distribution Equipment\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIndustrial Control\u003c\/td\u003e \u003ctd\u003ePanels\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eBJL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eEverlink Lug Both Ends\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e125A\/BJ\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eUnit Mount\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e5.39 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e3.19 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901016533\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D BJL36020 is a molded case circuit breaker from the POWERPACT B Series. It is a 3-pole, 20 A unit rated for 347\/600V AC with a maximum AIR rating of 100kA at 120\/240V AC. This standard thermal magnetic breaker features Everlink lug connections on both ends and a unit mount style.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647393038549,"sku":"BJL36020","price":1769.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z1wt-whcpEx.jpg?v=1791173924"},{"product_id":"tm30420c","title":"TM30420C Ge Load Center, TM304, THQL, 30 Spaces, 200A, 120\/208V, Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 30\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/208V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e THQL\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover:\u003c\/strong\u003e Combination Flush\/Surface\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eTM30420C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eGe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e30\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e120\/208V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eTHQL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover\u003c\/td\u003e \u003ctd\u003eCombination Flush\/Surface\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eMain Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eTM304\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e36.8 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e15.36 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3 22\/25 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With GE\u003c\/td\u003e \u003ctd\u003eTHQL Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material\u003c\/td\u003e \u003ctd\u003eAluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e22kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Attachment Style Screw\u003c\/td\u003e \u003ctd\u003eOn\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCover Closure Method\u003c\/td\u003e \u003ctd\u003eDoor Handle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e783164190021\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Ge TM30420C is a 3-phase load center with 30 spaces and a 200 A main circuit breaker for 120\/208V AC service. It uses THQL circuit breakers, has an aluminum bus, and is rated for 22kA short circuit current. The unit includes a combination flush\/surface enclosure cover with a door handle and screw-on attachment, measuring 36.8 in high, 15.36 in wide, and 3 22\/25 in deep.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Ge","offers":[{"title":"Default Title","offer_id":67647397003477,"sku":"TM30420C","price":1587.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0qLFtjcpIx.jpg?v=1791173948"},{"product_id":"qdl32150","title":"QDL32150 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 150A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 1,200 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDL32150\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3.93 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901662648\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDL32150 is a molded case circuit breaker from the QD series. It is a 3-pole, 150 A, 240V AC unit with a maximum AIR rating of 25kA at 240V AC. This thermal magnetic breaker has a fixed instantaneous trip, lug terminal connection, and a 250A\/QD frame size.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647412863189,"sku":"QDL32150","price":1731.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-5M2vfo5oy.jpg?v=1791174067"},{"product_id":"qo342mq200","title":"QO342MQ200 Square D Load Center, QO, 42 Spaces, 200A, 120\/240V AC, Convertible Main Circuit Breaker, 3 Phase","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eNumber of Spaces:\u003c\/strong\u003e 42\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVoltage:\u003c\/strong\u003e 208Y\/120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e QO\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eIncluded Enclosure Cover:\u003c\/strong\u003e Order Separately\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMain Circuit Breaker or Main Lug:\u003c\/strong\u003e Convertible, Main Circuit Breaker\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQO342MQ200\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eLoad Center\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Spaces\u003c\/td\u003e \u003ctd\u003e42\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e208Y\/120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluded Enclosure Cover\u003c\/td\u003e \u003ctd\u003eOrder Separately\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMain Circuit Breaker or Main Lug\u003c\/td\u003e \u003ctd\u003eConvertible, Main Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. No. of Tandem Breakers\u003c\/td\u003e \u003ctd\u003e0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e39.38 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e14.25 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3 3\/4 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eQO Circuit Breakers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBus Material Tin Plated\u003c\/td\u003e \u003ctd\u003eCopper\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current Rating\u003c\/td\u003e \u003ctd\u003e25kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEnclosure NEMA Rating\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRecommended Flush Cover\u003c\/td\u003e \u003ctd\u003e3XB93\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901290568\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QO342MQ200 is a three-phase QO load center with 42 spaces and a 200 A rating at 208Y\/120\/240V AC. It has a convertible main circuit breaker, a tin-plated copper bus, and a short circuit current rating of 25kA. The enclosure is NEMA 1 rated, and the cover is ordered separately.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647415845077,"sku":"QO342MQ200","price":1726.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0J0xufo5oy.jpg?v=1791174089"},{"product_id":"qdl32175","title":"QDL32175 Square D Molded Case Circuit Breaker, POWERPACT Q Series, 175A, 3 Pole, 240V AC, 25kA at 240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 175 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMax. AIR Rating:\u003c\/strong\u003e 25kA at 240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSeries:\u003c\/strong\u003e QD\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh Amp Trip Setting:\u003c\/strong\u003e 2,400 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow Amp Trip Setting:\u003c\/strong\u003e 1,200 A\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQDL32175\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e175 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e25kA at 240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHigh Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e2,400 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Amp Trip Setting\u003c\/td\u003e \u003ctd\u003e1,200 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Type\u003c\/td\u003e \u003ctd\u003eThermal Magnetic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eThree\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstantaneous Trip\u003c\/td\u003e \u003ctd\u003eFixed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Connection\u003c\/td\u003e \u003ctd\u003eABC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e250A\/QD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style Free\u003c\/td\u003e \u003ctd\u003eStanding\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e6.47 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e4.5 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e3.93 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFeatures\u003c\/td\u003e \u003ctd\u003eFor Use With -\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901523062\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QDL32175 is a molded case circuit breaker from the QD series. This 3-pole, three-phase unit is rated for 175 A and 240V AC, with a maximum AIR rating of 25kA at 240V AC. It has a thermal magnetic trip type, fixed instantaneous trip, lug terminal connections, and a free-standing mounting style.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647417123029,"sku":"QDL32175","price":1725.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z0J3ptfo5oy.jpg?v=1791174098"},{"product_id":"qob2150vh","title":"QOB2150VH Square D Miniature Circuit Breaker, QO Series, 150A, 2 Pole, 120\/240V AC, 22kA at 120\/240V AC","description":"\u003cul\u003e \u003cli\u003e \u003cstrong\u003eAmps:\u003c\/strong\u003e 150 A\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e 120\/240V AC\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Type High:\u003c\/strong\u003e Interrupting Capacity\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 2\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eDC Voltage Rating:\u003c\/strong\u003e Not Rated\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCircuit Breaker Actuator:\u003c\/strong\u003e Paddle\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003eQOB2150VH\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eSquare D\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eItem\u003c\/td\u003e \u003ctd\u003eMiniature Circuit Breaker\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmps\u003c\/td\u003e \u003ctd\u003e150 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC Voltage Rating\u003c\/td\u003e \u003ctd\u003e120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type High\u003c\/td\u003e \u003ctd\u003eInterrupting Capacity\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNumber of Poles\u003c\/td\u003e \u003ctd\u003e2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC Voltage Rating\u003c\/td\u003e \u003ctd\u003eNot Rated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Actuator\u003c\/td\u003e \u003ctd\u003ePaddle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Mounting Style\u003c\/td\u003e \u003ctd\u003eBolt On\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCompatible Panelboard\/Load Center Series\u003c\/td\u003e \u003ctd\u003eQO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase\u003c\/td\u003e \u003ctd\u003eSingle\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eQOB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax. AIR Rating\u003c\/td\u003e \u003ctd\u003e22kA at 120\/240V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFor Use With Square D\u003c\/td\u003e \u003ctd\u003eNQOD Panelboards\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTerminal Connection\u003c\/td\u003e \u003ctd\u003eLug\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrame Size\u003c\/td\u003e \u003ctd\u003e100A\/QO\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLength\u003c\/td\u003e \u003ctd\u003e5.7 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e3 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDepth\u003c\/td\u003e \u003ctd\u003e4.9 in\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUPC\u003c\/td\u003e \u003ctd\u003e785901065272\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Square D QOB2150VH is a miniature circuit breaker from the QOB series with a 150 A rating and two poles. It is rated for 120\/240V AC with a maximum AIR of 22kA at 120\/240V AC. This bolt-on unit features a paddle actuator, lug terminal connection, and is for use with Square D NQOD panelboards.\u003c\/p\u003e\u003cp\u003eConfirm the part number against your existing unit or equipment before ordering to ensure correct fit.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":67647420137685,"sku":"QOB2150VH","price":1718.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/9091\/2213\/files\/Z-2A1xfo5oy.jpg?v=1791174120"}],"url":"https:\/\/proreplacementparts.com\/collections\/circuit-protection.oembed","provider":"Pro Replacement Parts","version":"1.0","type":"link"}